Improved determination of aluminum in serum by electrothermal atomic absorption spectrophotometry.
نویسندگان
چکیده
This method for determining aluminum in human serum involves electrothermal atomic absorption spectrophotometry. A longer drying time allows less pre-dilution of the sample, and the method also includes a flush cycle after atomization. Standard-addition methodology is used to eliminate matrix effects and the need for a standard curve. We used this method on serum from 50 normal persons and from 34 patients with chronic renal failure who were on long-term intermittent hemodialysis. The mean normal serum aluminum concentration was 6.1 micrograms/L (CV 2.7%), and values for the patients ranged from 13 to 475 micrograms/L.
منابع مشابه
Electrothermal atomic absorption spectrometric determination of aluminum: elimination of serum matrix effects.
An improved electrothermal atomic absorption spectrometric method for determination of aluminum in serum is described. An ammonium hydroxide/sulfuric acid diluent is used to control matrix effects from serum constituents. Because serum produces no apparent matrix effects with this diluent, one can accurately calibrate the procedure with aqueous standards.
متن کاملDetermination of nickel in biological samples prepared by microwave dissolution using electrothermal atomic absorption spectrometry after extraction with l,Sbis[phenyl-( 2-pyridyl) methylene] thiocarbonhydrazide
An electrothermal atomization atomic absorption spectrometric method for the determination of traces of nickel atIer extraction of the metal into methyl isobutyl ketone containing 1,5-bis[phenyl(2-pyridylhnethylene] thiocarbonhydrazide is suggested. The chief advantage of the method lies in its maximum allowable aqueous-to-organic phase volume ratio of 37. The method was applied to the determin...
متن کاملDetermination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملImproved determination of vanadium in biological fluids by electrothermal atomic absorption spectrometry.
We made sensitive and accurate electrothermal atomic absorption spectrometric measurements of vanadium in small volumes of serum. The wet-digested sample was extracted into an organic solvent, with N-benzoyl-N-(o-tolyl)hydroxylamine (BTA) as the chelating reagent. After evaporating the solvent, we dissolved the residue in acetic acid, and injected a 60-microL aliquot into a graphite furnace. In...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 29 6 شماره
صفحات -
تاریخ انتشار 1983