Factors affecting the predictability of SRK II in patients with normal axial length undergoing phacoemulsification surgery.

نویسندگان

  • L H Lim
  • S Y Lee
  • C L Ang
چکیده

INTRODUCTION This study aims to evaluate the factors affecting the accuracy of biometry assessment using the SRK II formula in predicting the refractive outcome after uneventful cataract surgery by phacoemulsification for eyes within the normal range of axial lengths. METHODS A retrospective review of 100 consecutive cases of uncomplicated phacoemulsification surgery performed by two surgeons from January to September 2005 in a single centre was done. Eyes with axial length greater than or equal to 22.5 mm and less than 24.5 mm were included in the study. The error of prediction was calculated by actual postoperative refractive error minus the refraction target. A comparison was made between the low predictability (prediction error more than 0.50 dioptres [D]) and high predictability (prediction error less than or equal to 0.50 D) groups of eyes. Statistical analysis was performed. RESULTS A total of 267 case notes were reviewed, of which 100 met the inclusion criteria. The mean age was 68.3 years, with a mean keratometric reading of 43.94 +/- 1.27 D and mean axial length of 23.38 +/- 0.51 mm. The mean IOL power used was 21.77 +/- 1.50 D. The mean error was +0.25 +/- 0.67 (range -1.58 to +1.80) D, with the standard error of mean 0.669. 45 percent of the patients were within 0.5 D of the predicted refractive error and 83 percent were within 1.0 D. There was no difference in preoperative corneal astigmatism, mean keratometry, axial length, age or gender of the patient, laterality of the operated eye and intraocular lens power between the low and high predictability groups. There was a negative correlation between the axial length and prediction error. CONCLUSION SRK II is reliable in the prediction of the refractive outcome in normal axial length eyes. The findings in our study are comparable to those found in previous studies. We found a negative correlation between axial length and prediction error, even within the range of normal axial length eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive Predictability of Partial Coherence Interferometry and Factors that can Affect It

PURPOSE To evaluate the refractive predictability of a partial coherence interferometry (PCI) biometry device (IOL Master) for cataract surgery and to investigate factors that may affect it. METHODS Retrospective review of 209 eyes from 151 patients that had undergone preoperative PCI biometry and an uneventful phacoemulsification cataract surgery with posterior chamber intraocular lens (IOL)...

متن کامل

Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.

PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicon...

متن کامل

Predicting the refractive outcome after cataract surgery: the comparison of different IOLs and SRK-II v SRK-T.

AIM To determine any differences between the predictive abilities of the IOL calculation formulas of SRK-II and SRK-T and to compare these using two different IOL types. METHODS A prospective, consecutive, single surgeon clinical trial was conducted on 400 consecutive patients who received routine, standardised phacoemulsification cataract surgery. 200 had cataract surgery and had the Alcon M...

متن کامل

SCIENTIFIC CORRESPONDENCE Predicting the refractive outcome after cataract surgery: the comparison of different IOLs and SRK-II v SRK-T

Aim: To determine any differences between the predictive abilities of the IOL calculation formulas of SRK-II and SRK-T and to compare these using two different IOL types. Methods: A prospective, consecutive, single surgeon clinical trial was conducted on 400 consecutive patients who received routine, standardised phacoemulsification cataract surgery. 200 had cataract surgery and had the Alcon M...

متن کامل

Investigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification

Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Singapore medical journal

دوره 50 2  شماره 

صفحات  -

تاریخ انتشار 2009