Adhesive capabilities of Staphylococcus aureus and Pseudomonas aeruginosa isolated from tears of HIV/AIDS patients to soft contact lenses.
نویسندگان
چکیده
Fifty conjunctival swab samples collected from ELISA confirmed HIV/AIDS seropositive patients who were referred to the HIV/AIDS laboratories of the University of Benin Teaching Hospital and Central Hospital both based in Benin City, Nigeria were aseptically cultured on appropriate media by standard methods. The resulting isolates/strains, after identification by standard methods, were tested for their ability to adhere to two hydrophobic non-ionic daily wear silicone hydrogel soft contact lenses (i.e. lotrafilcon B, WC 33% and polymacon, WC 38%) as well as to two hydrophilic ionic conventional extended wear silicone hydrogel soft contact lenses (i.e. methafilcon A, WC 55% and omafilcon A, WC 60%) by the adhesiveness/slime production modified vortex/Robin device method. Evidence of adhesiveness/slime production was indicated by presence of a visible stained film lining the surface of the contact lens which was measured and recorded as strong or weak according to the density of the adhered bacterial film. Fourteen (28.0%) Staphylococcus aureus strains and 10 (20.0%) Pseudomonas aeruginosa strains were obtained among other organisms. Staphylococcus aureus strains adhered in decreasing order to lotrafilcon B (55.4 ± 4.7), polymacon (46.4 ± 8.4), methfilcon A (46.4 ± 8.4) and omafilcon A (25.0 ± 6.4) with no significant difference in adhesive strengths of individual strains (P > 0.05). Pseudomonas aeruginosa strains also recorded decreasing adhesive strengths to lotrafilcon B (37.5 ± 8.2), polymacon (28.6 ± 6.3), methafilcon A (26.8 ± 5.5) and omafilcon A (23.2 ± 5.5) also with no significant difference in adhesive strengths of individual strains (P > 0.05). Attachment strengths of Staph. aureus strains to all four contact lenses were higher than those of Pseudomonas aeruginosa strains. Both organisms adhered most to hydrophobic lotrafilcon B and least to hydrophilic omafilcon A. This invitro adhesion studies revealed that daily wear silicone hydrogel low water content, non-ionic contact lenses are more prone to bacterial adhesion than the conventional extended wear hydrogel high water content, ionic contact lenses and hence, there is more risk of microbial adhesion to the former compared to the latter. Other implications are highlighted.
منابع مشابه
Sensitivity Pattern of Bacteria Isolated from Contact Lens Wearers in the Faculty of Pharmacy, Karachi University Student Population
Contact lens wearers are at great risk of developing microbial keratitis because of incorrect usages and unhygienic maintenance of contact lenses. Therefore, the present study was planned to provide data that will be helpful in selecting the anti-microbial to cure microbial keratitis. One hundred bacterial isolates from conjunctiva of contact lenses wearer were isolated, identified and subjecte...
متن کاملSensitivity Pattern of Bacteria Isolated from Contact Lens Wearers in the Faculty of Pharmacy, Karachi University Student Population
Contact lens wearers are at great risk of developing microbial keratitis because of incorrect usages and unhygienic maintenance of contact lenses. Therefore, the present study was planned to provide data that will be helpful in selecting the anti-microbial to cure microbial keratitis. One hundred bacterial isolates from conjunctiva of contact lenses wearer were isolated, identified and subjecte...
متن کاملThe Antibiofilm efficacy of nitric oxide on soft contact lenses
BACKGROUND To investigate the antibiofilm efficacy of nitric oxide (NO) on soft contact lenses. METHODS Nitrite (NO precursor) release from various concentrations (0-1000 μM) of sodium nitrite (NaNO2, NO donor) was measured by Griess Assay. Cell viability assay was performed using human corneal epithelial cell under various concentration (0-1000 μM) of NaNO2. Biofilm formation on soft contact...
متن کاملExtrachromosomal DNA Length and Antibiograms of Staphylococcus aureus and Pseudomonas aeruginosa Isolated from Tears of HIV/AIDS Patients after Curing with Sodium Dodecyl Sulphate
Staphylococcus aureus and Pseudomonas aeruginosa strains were isolated from eye swab samples randomly obtained from 100 seropositive HIV/AIDS patients who reported to various anti-retroviral treatment clinics at the University of Benin Teaching Hospital and Central Hospital both based in Benin City, Nigeria. Invitro antibiotic sensitivity patterns of strains before curing were determined by the...
متن کاملIsolation of Methicillin-Resistant Staphylococcus aureus (MRSA) from HIV Patients Referring to HIV Referral Center, Shiraz, Iran, 2011-2012
Extension of drug resistant Staphylococcus aureus strains is one of the problems of modern society. Presence of methicillin-resistant Staphylococcus aureus (MRSA) in HIV-infected individuals is an important cause of severe infections. Therefore, the main goal of this study was to determine the prevalence rate of MRSA carriage rate among HIV patients referring to the Shiraz HIV referral center (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Global journal of health science
دوره 4 1 شماره
صفحات -
تاریخ انتشار 2012