Effect of Photorefractive Keratectomy on Optic Nerve Head Topography and Retinal Nerve Fiber Layer Thickness Measured by Heidelberg Retina Tomograph 3

نویسندگان

  • Naveed Nilforushan
  • Pejvak Azadi
  • Reza Soudi
  • Yahya Shaheen
  • Kourosh Sheibani
چکیده

PURPOSE To determine whether photorefractive keratectomy (PRK) has a significant effect on optic nerve head (ONH) parameters and peripapillary retinal nerve fiber layer (RNFL) thickness measured by the Heidelberg Retina Tomograph 3 (Heidelberg Engineering GmbH, Heidelberg, Germany) in eyes with low to moderate myopia. METHODS This prospective, interventional case series, includes 43 consecutive myopic eyes which were assessed on the day of PRK and 3 months postoperatively using the HRT3. Among the stereometric parameters, we compared disc area, linear cup disc ratio, cup shape measure, global rim area, global rim volume, RNFL height variation contour and mean RNFL thickness; out of the Glaucoma Probability Score (GPS) we assessed changes in global value, rim steepness temporal/superior, and temporal/inferior, as well as cup size and cup depth before and after PRK. RESULTS Mean refractive error before and after PRK were -3.24 ± 1.31 and -0.20 ± 0.42 diopters, respectively. No significant change occurred in disc area, linear cup disc ratio, cup shape measure, rim area and rim volume among the stereometric parameters; and in rim steepness temporal/superior and rim steepness temporal/inferior in the GPS before and after PRK using the default average keratometry. However, RNFL height variation contour, mean RNFL thickness, and cup size and depth were significantly altered after PRK (P < 0.05). CONCLUSION PRK can affect some HRT3 parameters. Although the most important stereometric parameters for differentiating normal, suspect or glaucomatous patients such as rim and cup measurements in stereometric parameters were not changed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer.

PURPOSE To compare retinal nerve fiber layer (RNFL) thickness measured by Heidelberg retina tomograph (HRT) and nerve fiber analyzer (GDx). METHODS Twenty eyes of 20 consecutive healthy subjects were recruited for this study. Each subject had a normal visual field and a normal optic nerve head, which was assessed by slit-lamp biomicroscopy using a 90 degrees lens. Using the HRT and GDx, RNFL ...

متن کامل

Symmetry of optic nerve head parameters measured by the heidelberg retina tomograph 3 in healthy eyes: the Blue Mountains Eye study.

PURPOSE To assess the symmetry of optic nerve head parameters measured by the Heidelberg Retina Tomograph 3 (HRT 3) between fellow eyes in a normal elderly population. DESIGN Cross-sectional population-based study. METHODS Participants of the Blue Mountains Eye Study 10-year follow-up who did not have optic disc disease, including glaucoma, were included. Optic nerve head parameters measure...

متن کامل

Macular Retinal Ganglion Cell Complex Thickness and Its Relationship to the Optic Nerve Head Topography in Glaucomatous Eyes with Hemifield Defects

Purpose. To evaluate the relationship between the macular ganglion cell complex (mGCC) thickness, which is the sum of the retinal nerve fiber, ganglion cell, and inner plexiform layers, measured with a spectral-domain optical coherence tomograph and the optic nerve head topography measured with a confocal scanning laser ophthalmoscope in glaucomatous eyes with visual field defects localized pre...

متن کامل

Comparison of optic disc topography measured by Retinal Thickness Analyzer with measurement by Heidelberg Retina Tomograph II.

PURPOSE To compare the optic disc topography measurements from a digitized laser slit-lamp and a confocal scanning laser ophthalmoscope (SLO). METHODS Ten normal subjects (10 eyes) were recruited. Topographic measurements of the optic disc were performed three times in all eyes using the Retinal Thickness Analyzer (RTA) and the Heidelberg Retina Tomograph II (HRT II), and the mean values dete...

متن کامل

Changes in the thickness of the macular ganglion cell complex and retinal nerve fiber layer over time after surgery in a case of juvenile glaucoma

Purpose To report longitudinal changes over time after surgery in the topography of the optic disc, thickness of the circum papillary retinal nerve fiber layer (c-RNFL), and thickness of the macular ganglion cell complex (m-GCC) in a case of juvenile open angle glaucoma. Observations Case report based on one patient. After significant edema of the optic disc for 2 months, the cup depth and cu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016