Flow in hemodialysis grafts after angioplasty: Do radiologic criteria predict success?
نویسندگان
چکیده
BACKGROUND The anatomic success of percutaneous angioplasty of venous stenosis is determined by the improvement in cross-sectional diameter of the vessel. A successful outcome is defined as a residual stenosis of <30%. The purpose of this study was to determine whether the angiographic assessment of a venous stenosis correlates with the change in graft blood flow following angioplasty. METHODS Twenty-two hemodialysis patients with decreased intragraft blood flow (<700 mL/min) underwent diagnostic fistulography and angioplasty. All grafts were patent at the time of the procedure. Intragraft blood flow was measured before and after angioplasty using the ultrasonic dilution technique. Change in graft blood flow after angioplasty was correlated to the morphologic changes of the treated stenosis. RESULTS The mean preangioplasty and postangioplasty graft blood flows were 457 +/- 136 and 818 +/- 202 mL/min, respectively. The mean degree of stenosis before angioplasty was 74 +/- 15% and 18 +/- 14% after dilation (P < 0.001). The only variable that significantly correlated with postangioplasty blood flow was preangioplasty flow (r2 = 0.22, P < 0.001). The postangioplasty blood flow was not significantly different than the highest recorded blood flow measured in that graft (798 +/- 213 mL/min, P = NS). There was no significant correlation between the change in blood flow and the change in percentage of stenosis. CONCLUSION Following angioplasty of a venous stenosis, the graft blood flow is most closely predicted by the preprocedural blood flow and is similar to the highest recorded blood flow ever measured in that graft. Angiographic criteria to assess the success of angioplasty are not predictive of changes in blood flow.
منابع مشابه
Use of stents and stent grafts to salvage angioplasty failures in patients with hemodialysis grafts.
To determine the efficacy of using stents and stent grafts for treatment of hemodialysis graft-related stenoses which have failed angioplasty. This retrospective study was composed of 51 patients with polytetrafluoroethylene hemodialysis grafts who underwent angioplasty of a graft-related stenosis but subsequently required insertion of a stent or stent graft. The study group included 40 patient...
متن کاملStent graft versus balloon angioplasty for failing dialysis access grafts: a long-awaited advance in the treatment of permanent hemodialysis access.
Arteriovenous grafts (AVGs) for hemodialysis have a high failure rate, often due to the development of stenosis at the graft-to-vein anastomosis. Angioplasty (PTA) has been used for over two decades to treat AVG stenosis, with good technical success but limited AVG patency. Results of a prospective multi-center randomized trial, comparing stent graft to PTA in AVGs, has demonstrated superior ac...
متن کاملInitial experience during balloon angioplasty assisted surgical thrombectomy for thrombosed hemodialysis grafts.
BACKGROUND Access failure in hemodialysis patients is commonly encountered by vascular surgeons. Researchers have reported various solutions for dealing with clotted grafts, including thrombectomy, thrombolysis, interposition grafting, angioplasty, or a combination of these methods. Surgical thrombectomy has been the standard procedure for dealing with thrombosed hemodialysis grafts in the card...
متن کاملUse of a catheter-based system to measure blood flow in hemodialysis grafts during angioplasty procedures.
PURPOSE The goals of this investigation were to evaluate the accuracy and reliability of the Angioflow meter system with use of in vitro and in vivo methods and to compare it to the standard Transonics HD01 system in a clinical setting. MATERIALS AND METHODS The Angioflow meter system consists of a 6-F endovascular catheter and a laptop computer containing proprietary software for this applic...
متن کاملInvasive radiologic management of hemodialysis fistulas: measuring flow with an endovascular catheter.
OBJECTIVES To analyze the values of flow obtained with an endovascular catheter, and to determine whether they are more reliable than angiographic and clinical findings for planning and for determining the outcome of invasive radiologic treatment of hemodialysis fistulas, as well as to determine the safety of this technique during interventional radiology procedures. MATERIAL AND METHODS We u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kidney international
دوره 59 5 شماره
صفحات -
تاریخ انتشار 2001