Choroidal laser Doppler flowmeter with enhanced sensitivity based on a scattering plate.
نویسندگان
چکیده
A portable choroidal laser Doppler flowmeter (LDF) with enhanced sensitivity based on a scattering plate is developed. The portable LDF is weighted 2 kg operated at center wavelength of 780 nm, leading to a better penetration into the eye fundus in contrast to the previous LDF operated at center wavelength of 670 nm. Enhancement of number of detected photons that undergo Doppler scattering and improved measured speed of choroidal blood flow are achieved with the use of a scattering plate positioned in front of the eye. The mechanism of detection and sensitivity enhancement is theoretically analyzed. Evaluation of system performance is done by in vivo measurements on ten volunteers. The results demonstrate that an increased percentage of backscattering light at high Doppler shift frequency is collected due to utilization of the scattering plate. However, this kind of light detection influences spatial resolution of the system and decreases the total signal measured. The proposed method for detection and sensitivity enhancement might be useful in a case where the perception of very slight alternation of blood flow is pursued and the spatial resolution is not as critical as that in a choroidal vascular bed.
منابع مشابه
Choroidal blood flow in AMD.
In a recent article in this journal, Grunwald et al. 1 quantified foveolar choroidal blood flow using a Laser Doppler flowmeter in patients with nonexudative age-related macular degeneration (AMD). They found that choroidal blood volume and choroidal blood flow in patients with AMD were significantly reduced. However, they found no statistically significant difference for the choroidal blood ve...
متن کاملInability of a Confocal Scanning Laser Doppler Flowmeter to Measure Choroidal Blood Flow in the Pig Eye
The aim of the study was to determine whether the Heidelberg Retinal Flowmeter (HRF), a confocal scanning laser Doppler flowmeter, can measure choroidal blood flow in pig eyes.An HRF was used to obtain flow maps from in vitro pig eyes under a range of perfusion flow rates (0 - 500 microL/min) under conditions in which only the choroid was perfused. In some cases choroidal blood flow was also me...
متن کاملA novel, microscope based, non-invasive laser Doppler flowmeter for choroidal blood flow assessment.
Impaired ocular blood flow is involved in the pathogenesis of numerous ocular diseases like glaucoma or AMD. The purpose of the present study was to introduce and validate a novel, microscope based, non-invasive Laser Doppler Flowmeter (NI-LDF) for measurement of blood flow in the choroid. The custom made NI-LDF was compared with a commercial fiber optic based laser Doppler flowmeter (Perimed P...
متن کاملSchlieren laser Doppler flowmeter for the human optical nerve head with the flicker stimuli.
We describe a device to measure blood perfusion for the human optic nerve head (ONH) based on laser Doppler flowmetry (LDF) with a flicker stimuli of the fovea region. This device is self-aligned for LDF measurements and includes near-infrared pupil observation, green illumination, and observation of the ONH. The optical system of the flowmeter is based on a Schlieren arrangement which collects...
متن کاملOptical Limiting Properties of Colloids Enhanced by Gold Nanoparticles Based on Nonlinear Refraction for Cw Laser Illumination
In this work, thermo-optical properties of gold nanoparticle colloids are studied using continuous wave (CW) laser irradiation at 532 nm. The nanoparticle colloids are fabricated by 18 ns pulsed laser ablation of pure gold plate in the distilled water. The formation of the nanoparticles has been evidenced by optical absorption spectra and transmission electron microscopy. The nonlinear optical ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 16 4 شماره
صفحات -
تاریخ انتشار 2011