Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.
نویسندگان
چکیده
To generate real-time, nongated, free-breathing cardiac images, the undersampled radial trajectory combined with parallel imaging in the form of radial GRAPPA has shown promise. However, this method starts to fail at high undersampling factors due to the assumptions that must be made for the purposes of calibrating the GRAPPA weight sets. In this manuscript, a novel through-time radial GRAPPA calibration scheme is proposed which greatly improves image quality for the high acceleration factors required for real-time cardiac imaging. This through-time calibration method offers better image quality than standard radial GRAPPA, but it requires many additional calibration frames to be acquired. By combining the through-time calibration method proposed here with the standard through-k-space radial GRAPPA calibration method, images with high acceleration factors can be reconstructed using few calibration frames. Both the through-time and the hybrid through-time/through-k-space methods are investigated to determine the most advantageous calibration parameters for an R = 6 in vivo short-axis cardiac image. Once the calibration parameters have been established, they are then used to reconstruct several in vivo real-time, free-breathing cardiac datasets with temporal resolutions better than 45 msec, including one with a temporal resolution of 35 msec and an in-plane resolution of 1.56 mm(2) .
منابع مشابه
A comparison of real-time radial GRAPPA and standard cine imaging for the evaluation of cardiac function in children and young adults
Background Segmented balanced steady state free precession (bSSFP) cine imaging is the gold standard MRI technique for assessing ventricular systolic function. The image acquisition involves ECG gating and is ideally performed during breath-hold to reduce artifacts from myocardial and respiratory motion. Real-time radial imaging with parallel imaging technique GRAPPA reconstruction (radial GRAP...
متن کاملSelf-calibrating through-time spiral GRAPPA for real-time CMR
Background Through-Time non-Cartesian GRAPPA, a novel parallel imaging method for non-Cartesian trajectories, has recently been shown to provide real-time, free-breathing cardiac images with temporal resolutions of less than 35 ms per frame [Seiberlich N, et al. MRM 2011 Dec;66 (6):1682-8]. The drawback to this method is the need for several fully-sampled datasets for calibration stemming from ...
متن کاملEvaluation of through-time radial GRAPPA for functional cardiac imaging in a patient population
Methods 63 patients scheduled for routine CMR examinations were scanned on a 1.5T Siemens Avanto scanner with 12-18 receiver coils in this IRB and HIPPA-compliant study. The gold-standard gated and breathheld shortaxis cardiac functional examination was performed for each patient with a temporal resolution between 31 and 62 ms, GRAPPA R = 2, and an in-plane resolution between 1.4-2.6 mm. Real-t...
متن کاملThrough-Time Spiral GRAPPA for Real-Time Cardiac Imaging
Introduction: Accelerated data acquisition followed by parallel imaging reconstruction has been used in cardiac imaging to reduce imaging times and avoid artifacts due to motion. Coupled with non-Cartesian trajectories, such parallel imaging techniques can yield images with high acceleration factors with little residual aliasing. Recently, a method has been proposed which improves the radial GR...
متن کاملEvaluation of left ventricular ejection fraction using through-time radial GRAPPA
BACKGROUND The determination of left ventricular ejection fraction using cardiovascular magnetic resonance (CMR) requires a steady cardiac rhythm for electrocardiogram (ECG) gating and multiple breathholds to minimize respiratory motion artifacts, which often leads to scan times of several minutes. The need for gating and breathholding can be eliminated by employing real-time CMR methods such a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 65 2 شماره
صفحات -
تاریخ انتشار 2011