Images in cardiovascular medicine. Augmentation of coronary blood flow with intra-aortic balloon pump counter-pulsation.
نویسندگان
چکیده
Intra-Aortic Balloon Pump Counter-Pulsation To the Editor: The imaging of coronary flow1 during intra-aortic balloon pumping is important and might be used to adjust the timing of balloon deflation better. In the series of figures shown by Ryan and Foster,1 with intra-aortic balloon pumping assisting every second beat, there was no consistent reduction of systolic pressure in the intervening unassisted beat, which suggests that balloon deflation may have been premature.2 Further, in the assisted beat, coronary flow, although having a higher peak, appeared to be of shorter duration than in the unassisted beat. Have the authors considered the possibility that their technique may help optimize balloon deflation by ensuring maintenance of coronary perfusion throughout the diastolic period?
منابع مشابه
The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملAugmentation of Coronary Blood Flow by Intra - aortic Balloon Pumping in Patients After Coronary
Background. Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloo...
متن کاملAugmentation of Coronary Blood Flow by Intra - aortic Balloon Pumping in Patients After Coronary Angioplast Morton
Background. Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloo...
متن کاملAugmentation of Coronary Blood Flow by Intra - aortic Balloon Pumping in Patients After Coronary Angioplast
Background. Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloo...
متن کاملAugmentation of coronary blood flow by intra-aortic balloon pumping in patients after coronary angioplasty.
BACKGROUND Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloon...