Anisotropic partial volume CSF modeling for EEG source localization

نویسندگان

  • Damon Hyde
  • Frank H. Duffy
  • Simon K. Warfield
چکیده

Electromagnetic source localization (ESL) provides non-invasive evaluation of brain electrical activity for neurology research and clinical evaluation of neurological disorders such as epilepsy. Accurate ESL results are dependent upon the use of patient specific models of bioelectric conductivity. While the effects of anisotropic conductivities in the skull and white matter have been previously studied, little attention has been paid to the accurate modeling of the highly conductive cerebrospinal fluid (CSF) region. This study examines the effect that partial volume errors in CSF segmentations have upon the ESL bioelectric model. These errors arise when segmenting sulcal channels whose widths are similar to the resolution of the magnetic resonance (MR) images used for segmentation, as some voxels containing both CSF and gray matter cannot be definitively assigned a single label. These problems, particularly prevalent in pediatric populations, make voxelwise segmentation of CSF compartments a difficult problem. Given the high conductivity of CSF, errors in modeling this region may result in large errors in the bioelectric model. We introduce here a new approach for using estimates of partial volume fractions in the construction of patient specific bioelectric models. In regions where partial volume errors are expected, we use a layered gray matter-CSF model to construct equivalent anisotropic conductivity tensors. This allows us to account for the inhomogeneity of the tissue within each voxel. Using this approach, we are able to reduce the error in the resulting bioelectric models, as evaluated against a known high resolution model. Additionally, this model permits us to evaluate the effects of sulci modeling errors and quantify the mean error as a function of the change in sulci width. Our results suggest that both under and over-estimation of the CSF region leads to significant errors in the bioelectric model. While a model with fixed partial volume fraction is able to reduce this error, we see the largest improvement when using voxel specific partial volume estimates. Our cross-model analyses suggest that an approximately linear relationship exists between sulci error and the error in the resulting bioelectric model. Given the difficulty of accurately segmenting narrow sulcal channels, this suggests that our approach may be capable of improving the accuracy of patient specific bioelectric models by several percent, while introducing only minimal additional computational requirements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EEG source analysis of epileptiform activity using a 1 mm anisotropic hexahedra finite element head model

The major goal of the evaluation in presurgical epilepsy diagnosis for medically intractable patients is the precise reconstruction of the epileptogenic foci, preferably with non-invasive methods. This paper evaluates whether surface electroencephalography (EEG) source analysis based on a 1 mm anisotropic finite element (FE) head model can provide additional guidance for presurgical epilepsy di...

متن کامل

Influence of Tissue Conductivity Inhomogeneity and Anisotropy on EEG/MEG based Source Localization in the Human Brain

The inverse problem in Electroand Magneto-EncephaloGraphy (EEG/MEG) aims at reconstructing the underlying current distribution in the human brain using potential differences and/or magnetic fluxes that are measured non-invasively directly, or at a close distance, from the head surface. The solution requires repeated computation of the forward problem, i.e., the simulation of EEG and MEG fields ...

متن کامل

Combination of Beamforming and Synchronization Methods for Epileptic Source Localization, using Simulated EEG Signals

Localization of sources in patients with focal seizure has recently attracted many attentions. In the severe cases of focal seizure, there is a possibility of doing neurosurgery operation to remove the defected tissue. The prosperity of this heavy operation completely depends on the accuracy of source localization. To increase this accuracy, this paper presents a new weighted beamforming method...

متن کامل

Electrical Neuroimaging with Irrotational Sources

This paper discusses theoretical aspects of the modeling of the sources of the EEG (i.e., the bioelectromagnetic inverse problem or source localization problem). Using the Helmholtz decomposition (HD) of the current density vector (CDV) of the primary current into an irrotational (I) and a solenoidal (S) part we show that only the irrotational part can contribute to the EEG measurements. In par...

متن کامل

The Effect of Head Model Simplification on Beamformer Source Localization

Beamformers are a widely-used tool in brain analysis with magnetoencephalography (MEG) and electroencephalography (EEG). For the construction of the beamformer filters realistic head volume conductor modeling is necessary for accurately computing the EEG and MEG leadfields, i.e., for solving the EEG and MEG forward problem. In this work, we investigate the influence of including realistic head ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 62 3  شماره 

صفحات  -

تاریخ انتشار 2012