A comparison of HFA-BDP Autohaler with budesonide Turbuhaler in asthma control of adult patients with mild to moderately severe disease.
نویسنده
چکیده
Hydrofluoroalkane-134a (HFA) beclomethasone dipropionate (BDP) extrafine aerosol is a pressurized metered dose inhaler (pMD1) available for the treatment of asthma. Unlike most pMDIs, HFA-BDP is a solution, rather than a suspension, of BDP in HFA propellant. This reforrnulation, combined with improvements in inhaler technology, results in the production of aerosol particles of smaller mean mass aerodynamic diameter (MMAD) than produced from chlorofluorocarbon (CFC)-BDP inhalers, I.1 pm vs. 3.5-4 pm, respectively (1,2). Inhaled corticosteroids are increasingly recommended for first-line therapy in the management of asthma (3,4) with pMDIs the most commonly prescribed method of delivery. However, a significant proportion of patients fail to use pMDIs correctly, even with appropriate training. It has been reported that 50% of patients revert to their previous incorrect press and breathe inhaler technique following proper training (5). HFA-BDP as the AutohalerTM (AH) inhalation device has been shown to be of clinical benefit to patients with problems handling a press and breathe pMD1 (6). Drypowder inhalers (DPIs) such as the budesonide Turbuhaler@ (BUD TH), have also been designed to limit the handling difficulties encountered with traditional pMDIs. However, in contrast to HFA-BDP AH, DPIs remain breath dependent (i.e. drug delivery from the inhaler is dependent on inspiratory flow) (Fig. I) (7). While comparative dosing strategies for HFA-BDP AH and BUD, TH have,‘not yet been investigated, it is recognized that CFC-BDP and budesonide have similar therapeutic efficacy and safety profiles. In the past, these agents have been considered to be equipotent (9,10), but recently budesonide has been recognized to be somewhat more potent, especially if administered via the Turbuhaler@ (3,1 I). Given this, and the fact that HFA-BDP produces equivalent efficacy to CFC-BDP at approximately 2.5-times the daily steroid dose (12) it can be hypothesized that half the daily dose of HFA-BDP AH would provide equivalent control of asthma symptoms to the BUD TH. The
منابع مشابه
Growth, systemic safety, and efficacy during 1 year of asthma treatment with different beclomethasone dipropionate formulations: an open-label, randomized comparison of extrafine and conventional aerosols in children.
OBJECTIVE To assess the long-term safety of hydrofluoroalkane 134a (HFA)-beclomethasone dipropionate (BDP) extrafine aerosol administered by the Autohaler compared with chlorofluorocarbon (CFC)-BDP administered by a press-and-breathe metered-dose inhaler (pMDI) and spacer (+S) in the treatment of children with asthma. METHODS This 12-month, open-label, randomized, multicenter study enrolled 3...
متن کاملImproved control of asthma symptoms with a reduced dose of HFA-BDP extrafine aerosol: an open-label, randomised study.
BACKGROUND Extrafine aerosols may improve asthma symptom control through increased lung deposition of medication to inflamed peripheral airways. METHODS The effect of switching patients with asthma maintained on up to 2000 microg/day chlorofluorocarbon-beclomethasone dipropionate (CFC-BDP), 1600 microg/day budesonide, 1000 microg/day fluticasone, or 2000 microg/day flunisolide, to a reduced d...
متن کاملComparable effects of inhaled fluticasone propionate and budesonide on the HPA-axis in adult asthmatic patients.
This randomized, double-blind, double-dummy, multicentre cross-over study compared the effects on the hypothalamic-pituitary-adrenal (HPA) axis of fluticasone propionate (750 microg twice daily given via the Diskus) and budesonide (800 microg twice daily given via the Turbuhaler). Two treatment periods of 2 weeks each were preceded by a 2-week run-in period and separated by a 2-week washout per...
متن کاملTherapeutic comparison of a new budesonide/formoterol pMDI with budesonide pMDI and budesonide/formoterol DPI in asthma
BACKGROUND Budesonide/formoterol is an effective treatment for both asthma and chronic obstructive pulmonary disease. This study compared the efficacy and safety of a novel hydrofluoroalkane (HFA) pressurised metered-dose inhaler (pMDI) formulation of budesonide/formoterol with that of budesonide pMDI and budesonide/formoterol dry-powder inhaler (DPI; Turbuhaler). METHODS This was a 12-week, ...
متن کاملInhaled corticosteroid delivery systems: clinical role of a breath-actuated device.
Several devices have been developed to overcome the need to co-ordinate actuation with inhalation required during use of a pressurised metered dose inhaler (MDI) and to improve drug delivery to the lung. These include spacer attachments for MDIs, dry powder inhalers and breath-actuated MDIs. The breath-actuated Autohaler (3M Pharmaceuticals) is a compact, multidose inhaler device that, unlike d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory medicine
دوره 94 Suppl D شماره
صفحات -
تاریخ انتشار 2000