Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI).
نویسندگان
چکیده
Parallel imaging methods become increasingly available on clinical MR scanners. To investigate the potential of sensitivity-encoded single-shot EPI (SENSE-EPI) for functional MRI, five imaging protocols at different SENSE reduction factors (R) and matrix sizes were compared with respect to their noise characteristics and their sensitivity toward functional activation in a motor task examination. At constant echo times, SENSE-EPI was either used to shorten the single volume acquisition times (TR(min)) at matrix size 128 x 100 (22 slices) from 3.9 s (no SENSE) to 2.0 s at R = 3, or to increase the matrix size to 192 x 153 (22 slices), resulting in TR(min) = 5.3 s for R = 2 or TR(min) = 3.4 s for R = 3. At the lower resolution, the bisection of echo train length (R = 2) substantially reduced distortions and blurring, while signal-to-noise and statistical power (measured by cluster size and maximum t value per unit time) were hardly reduced. At R = 3 the additional gain in speed and distortion reduction was quite small, while signal-to-noise and statistical power dropped significantly. With enhanced spatial resolution the time course signal-to-noise was better than expected from theory for purely thermal noise because of a reduced contribution of physiological noise, and statistical power almost reached that of the regular, low-resolution single-shot EPI, with a slight drop off toward R = 3. Thus, SENSE-EPI allows to substantially increase speed and spatial resolution in fMRI. At SENSE reduction factors up to R = 2, the potential drawbacks regarding signal-to-noise and statistical power are almost negligible.
منابع مشابه
Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging.
The benefits of sensitivity-encoded (SENSE) echo-planar imaging (EPI) for functional MRI (fMRI) based on blood oxygen level-dependent (BOLD) contrast were quantitatively investigated at 1.5 T. For experiments with 3.4 x 3.4 x 4.0 mm(3) resolution, SENSE allowed the single-shot EPI image acquisition duration to be shortened from 24.1 to 12.4 ms, resulting in a reduced sensitivity to geometric di...
متن کاملImprovements in parallel imaging accelerated functional MRI using multiecho echo-planar imaging.
Multiecho echo-planar imaging (EPI) was implemented for blood-oxygenation-level-dependent functional MRI at 1.5 T and compared to single-echo EPI with and without parallel imaging acceleration. A time-normalized breath-hold task using a block design functional MRI protocol was carried out in combination with up to four echo trains per excitation and parallel imaging acceleration factors R = 1-3...
متن کامل[Study of aliasing ERROR with SENSE in body diffusion image using single-shot EPI at 3T].
Magnetic field inhomogeneity causes artifacts in MRI. For example, in single-shot echo-planar imaging (EPI), they often appear as severe geometric distortions along the phase-encoding direction. Sensitivity encoding (SENSE) is useful in reducing the distortion in EPI since it only acquires partial k-space data using multiple receiver channels. In SENSE, a reference scan usually needs to be perf...
متن کاملGeometric distortion correction in echo volumar imaging
Introduction: Echo volumar imaging (EVI) is a 3D extension of echo-planar imaging (EPI) that allows data from an entire volume to be acquired following a single excitation. However, only a few studies to date have applied EVI to functional MRI (fMRI) due to its high sensitivity to field-inhomogeneity induced distortions. In this study, we extend two EPI distortion correction techniques to EVI: ...
متن کاملHigh-Resolution Functional MRI at 3 T: 3D/2D Echo-Planar Imaging with Optimized Physiological Noise Correction
High-resolution functional MRI (fMRI) offers unique possibilities for studying human functional neuroanatomy. Although high-resolution fMRI has proven its potential at 7 T, most fMRI studies are still performed at rather low spatial resolution at 3 T. We optimized and compared single-shot two-dimensional echo-planar imaging (EPI) and multishot three-dimensional EPI high-resolution fMRI protocol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 19 2 Pt 1 شماره
صفحات -
تاریخ انتشار 2003