Prophylaxis of restenosis with (186)re-labeled stents in a rabbit model.

نویسندگان

  • G Tepe
  • L M Dinkelborg
  • U Brehme
  • P Muschick
  • B Noll
  • T Dietrich
  • A Greschniok
  • A Baumbach
  • C D Claussen
  • S H Duda
چکیده

BACKGROUND Intraluminal beta-irradiation has been shown to decrease neointimal proliferation after angioplasty in experimental models. The purpose of this study was to test the technical feasibility and biological effects of (186)Re-labeled stents. METHODS AND RESULTS Thirty-four New Zealand White rabbits were fed a 0.5% cholesterol diet before balloon angioplasty and insertion of Palmaz stents in the infrarenal aorta. The animals were killed 7 weeks after stent implantation. Two of 34 animals died prematurely (aortic leak, pneumonia). Control stents (n=7) were compared with (186)Re stents (2.6 MBq [n=6], 8.1 MBq [n=5], 16.0 MBq [n=6], and 25.3 MBq [n=8]). Stent application was successful in all cases. No thrombus occlusion was observed. After 7 weeks, neointima formation was 2.2+/-0.2 mm(2) in the control group. In the treatment groups, a dose-dependent neointima reduction was detectable (0.5+/-0.5 mm(2) [2.6 MBq], 0.4+/-0.4 mm(2) [8.1 MBq], and 0 mm(2) [16.0 MBq, 25.3 MBq]). No induction of neointimal formation was observed at the edges of the stents. Radiation resulted in delayed reendothelialization. CONCLUSIONS (186)Re stents were capable of reducing neointima formation in a dose-dependent fashion. (186)Re stents did not cause late thrombosis or neointimal induction at the stent margins in the observation period of 7 weeks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prophylaxis of Restenosis With Re-Labeled Stents in a Rabbit Model

Background—Intraluminal b-irradiation has been shown to decrease neointimal proliferation after angioplasty in experimental models. The purpose of this study was to test the technical feasibility and biological effects of Re-labeled stents. Methods and Results—Thirty-four New Zealand White rabbits were fed a 0.5% cholesterol diet before balloon angioplasty and insertion of Palmaz stents in the ...

متن کامل

Distinctive effects of CD34- and CD133-specific antibody-coated stents on re-endothelialization and in-stent restenosis at the early phase of vascular injury

It is not clear what effects of CD34- and CD133-specific antibody-coated stents have on re-endothelialization and in-stent restenosis (ISR) at the early phase of vascular injury. This study aims at determining the capabilities of different coatings on stents (e.g. gelatin, anti-CD133 and anti-CD34 antibodies) to promote adhesion and proliferation of endothelial progenitor cells (EPCs). The in v...

متن کامل

نتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت

Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...

متن کامل

Non-viral eNOS gene delivery and transfection with stents for the treatment of restenosis

BACKGROUND In this study, we have examined local non-viral gene delivery, transfection, and therapeutic efficacy of endothelial nitric oxide synthase (eNOS) encoding plasmid DNA administered using coated stents in a rabbit iliac artery restenosis model. METHODS Lipopolyplexes (LPPs) with eNOS expressing plasmid DNA were immobilized on stainless steel stents using poly(D,L-lactide-co-glycolide...

متن کامل

Effect of Atorvastatin-Eluting Stents in a Rabbit Iliac Artery Restenosis Model

Statins have pleiotropic effects, which include the inhibition of neointima hyperplasia, the inhibition of vascular inflammation, and platelet inhibition. The aim of this study was to examine the effect of an atorvastatin-eluting stent (AES) in a rabbit iliac artery overstretch restenosis model. Ten rabbits were used in this study (10 rabbits, 10 iliac arteries for each stent). An AES and pacli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 104 4  شماره 

صفحات  -

تاریخ انتشار 2001