Free-breathing 3D whole-heart black-blood imaging with motion sensitized driven equilibrium.

نویسندگان

  • Subashini Srinivasan
  • Peng Hu
  • Kraig V Kissinger
  • Beth Goddu
  • Lois Goepfert
  • Ehud J Schmidt
  • Sebastian Kozerke
  • Reza Nezafat
چکیده

PURPOSE To assess the efficacy and robustness of motion sensitized driven equilibrium (MSDE) for blood suppression in volumetric 3D whole-heart cardiac MR. MATERIALS AND METHODS To investigate the efficacy of MSDE on blood suppression and myocardial signal-to-noise ratio (SNR) loss on different imaging sequences, seven healthy adult subjects were imaged using 3D electrocardiogram (ECG)-triggered MSDE-prep T(1) -weighted turbo spin echo (TSE), and spoiled gradient echo (GRE), after optimization of MSDE parameters in a pilot study of five subjects. Imaging artifacts, myocardial and blood SNR were assessed. Subsequently, the feasibility of isotropic spatial resolution MSDE-prep black-blood was assessed in six subjects. Finally, 15 patients with known or suspected cardiovascular disease were recruited to be imaged using a conventional multislice 2D double inversion recovery (DIR) TSE imaging sequence and a 3D MSDE-prep spoiled GRE. RESULTS The MSDE-prep yielded significant blood suppression (75%-92%), enabling a volumetric 3D black-blood assessment of the whole heart with significantly improved visualization of the chamber walls. The MSDE-prep also allowed successful acquisition of black-blood images with isotropic spatial resolution. In the patient study, 3D black-blood MSDE-prep and DIR resulted in similar blood suppression in left ventricle and right ventricle walls but the MSDE-prep had superior myocardial signal and wall sharpness. CONCLUSION MSDE-prep allows volumetric black-blood imaging of the heart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of T1 contrast in whole-brain black-blood imaging using motion-sensitized driven-equilibrium prepared 3D turbo spin echo (3D MSDE-TSE).

We demonstrated a new scheme for performing the T1-enhanced whole-brain black-blood imaging pulse sequence using motion-sensitized driven-equilibrium prepared 3-dimensional (3D) turbo spin echo (MSDE-TSE) with anti-driven-equilibrium post pulse. The use of an anti-driven-equilibrium pulse considerably improved the T1 contrast of MSDE-TSE black-blood images. This sequence can be used for whole-b...

متن کامل

Interpretation of tissue contrast in a rapid black-blood gradient echo sequence with motion-sensitized driven equilibrium (MSDE) preparation (3D MERGE) for 3D isotropic high-resolution imaging of the vessel wall and its application for hemorrhage detection

Fig 3. Intarplaque hemorrhage: Bright signal on TOF (yellow arrow) corresponds to hyperintensity on reformatted axial and sagittal 3D-MERGE images. Interpretation of tissue contrast in a rapid black-blood gradient echo sequence with motion-sensitized driven equilibrium (MSDE) preparation (3D MERGE) for 3D isotropic high-resolution imaging of the vessel wall and its application for hemorrhage de...

متن کامل

Assessment of motion sensitized driven equilibrium (MSDE) improvement for whole brain application

INTRODUCTION: Contrast-Enhancement (CE) magnetic resonance imaging (MRI) is a promising modality for screening of brain metastasis (1). Paramagnetic contrast media exhibits metastatic lesions as hyper-intensities on T1W images. Because blood vessels are also enhanced, it is important to suppress the blood signal in order to reduce potential misdiagnoses (2). Although this can be achieved by a 3...

متن کامل

Clinical Assessment of motion sensitized driven equilibrium (MSDE) prepared T1W 3D vessel wall imaging at 3.0T for soft plaque screening

INTRODUCTION: Motion sensitized driven equilibrium (MSDE) prepared sequence has been proposed for fast black-blood vessel wall imaging (1, 2). Moreover, for detection of different kinds of plaques at the carotid artery wall, MSDE prepared 3D gradient echo sequence, optimized both for T1 and T2 contrasts, was proposed (3). This method allows wider anatomical coverage in short acquisition time co...

متن کامل

High-resolution whole-heart angiography with compressed sensing and 3D respiratory motion compensation in 5 minutes

Background The electrocardiogram and respiratory-gated 3D steadystate free precession (3D-SSFP) sequence acquired during free-breathing generates a high-resolution anatomic datasets of the entire thorax, allowing for a comprehensive evaluation of intracardiac, coronary, and vascular abnormalities. An important limitation of 3D-SSFP, however, is its long imaging time during which the patient’s h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 2012