An automated assessment of White Matter Lesions based on regional FLAIR intensity evaluation

نویسندگان

  • J. F. Jansen
  • P. A. Hofman
  • W. H. Backes
چکیده

Figure 2 Comparison of visually assessed and fully-automatically obtained white matter lesion values. A) comparison for subcortical white matter lesion (sWML) volumes, and B) comparison for periventricular white matter lesion (pWML) scores. The dotted line in A is the identity line. ρ = Spearman's rank correlation coefficient. An automated assessment of White Matter Lesions based on regional FLAIR intensity evaluation

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated White Matter Hyperintensity Detection in Multiple Sclerosis Using 3D T2 FLAIR

White matter hyperintensities (WMH) seen on T2WI are a hallmark of multiple sclerosis (MS) as it indicates inflammation associated with the disease. Automatic detection of the WMH can be valuable in diagnosing and monitoring of treatment effectiveness. T2 fluid attenuated inversion recovery (FLAIR) MR images provided good contrast between the lesions and other tissue; however the signal intensi...

متن کامل

An automated tool for detection of FLAIR-hyperintense white-matter lesions in Multiple Sclerosis

In Multiple Sclerosis (MS), detection of T2-hyperintense white matter (WM) lesions on magnetic resonance imaging (MRI) has become a crucial criterion for diagnosis and predicting prognosis in early disease. Automated lesion detection is not only desirable with regard to time and cost effectiveness but also constitutes a prerequisite to minimize user bias. Here, we developed and evaluated an alg...

متن کامل

Automatic quality assessment for multi-slice 2D FLAIR MR imaging

Introduction: Many clinical MRI protocols use the fluid attenuated inversion recovery (FLAIR) contrast to better delineate tissue abnormalities such as white matter lesions. Most FLAIR protocols acquire data in a 2D fashion. FLAIR images are often degraded by patient motion, especially when scanning uncooperative patients. Typical motion patterns induce inter-slice misalignment, ghosting and bl...

متن کامل

Automated White Matter Lesion Segmentation in MRI using Box-Whisker Plot Outlier Detection

We report a new automated method for White Matter Lesions (WMLs) Segmentation in cranial MR Imaging. WMLs are diffuse white matter abnormalities which are often presented as hyperintense regions. In our approach, the presence of these abnormalities are detected as outliers in the intensity distribution of the FLAIR sequence using the histogram tails analysis and Box-Whisker plot technique. In a...

متن کامل

The Assessment of Structural Changes in MS Plaques and Normal Appearing White Matter Using Quantitative Magnetization Transfer Imaging (MTI)

Introduction: Multiple sclerosis (MS) is a demyelinating disease of the central nervous system (CNS), affecting mostly young people at a mean age of 30 years. Magnetic resonance imaging (MRI) is one of the most specific and sensitive methods in diagnosing and detecting the evolution of multiple sclerosis disease. But it does not have the ability to differentiate between distinct histopathologic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007