Comparison of Shielding Data for 400 MeV/u Carbon Ion Beams

نویسندگان

  • G. Fehrenbacher
  • T. Radon
چکیده

Shielding data are necessary for the architectural planning of ion accelerator facilities. In the present case the main radiation component is neutron radiation. For the architectural planning in advance it is necessary to give a rough cost quotation for the shielding measures. In an early stage of a project rapid methods for the calculation of shielding thicknesses are required. Line-of-sight (LOS) models are used for this purpose. In this work parameters of line-of-sight models of various authors and groups are used [1, 2, 3] for a comparison of an experiment performed in the framework of the CONRAD measurement campaign carried out at GSI [4].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Secondary Particles Produced by Hadron Therapy

Introduction Use of hadron therapy as an advanced radiotherapy technique is increasing. In this method, secondary particles are produced through primary beam interactions with the beam-transport system and the patient’s body. In this study, Monte Carlo simulations were employed to determine the dose of produced secondary particles, particularly neutrons during treatment. Materials and Methods I...

متن کامل

Monte Carlo computation of dose deposited by carbon ions in radiation therapy

Background: High-velocity carbon ion beams represent the most advanced tool for radiotherapy of deep-seated tumors. Currently, the superiority of carbon ion therapy is more prominent on lung cancer or hepatomas. Materials and Methods: The data for lateral straggling and projected range of monoenergetic 290 MeV/u (3.48 GeV) carbon ions in muscle tissue were obtained from the stopping and range o...

متن کامل

Estimation of carbon-ion-caused radiation levels by calculating the transport of the produced neutrons through shielding layers

G. Fehrenbacher, F. Gutermuth, T. Radon GSI Darmstadt, Germany An important aspect to be considered when designing the GSI future project will be the radiation protection of both the staff and the environment. One of the prerequisites for a permission for the operation of a high-energy accelerator is a careful planning of the necessary radiation shielding equipment. In order to give recommendat...

متن کامل

Updating of HIMAC beam delivery with broad beam method

Carbon ion radiotherapy at HIMAC started in 1994 using two horizontal and two vertical beam ports with broad beam method. The maximum beam energy extracted from accelerators was 400 MeV/n for the horizontal beam port, and 350 MeV/n for the vertical one. In recent years, the scope of diseases that can be treated by the carbon ion radiotherapy has widened and their tumor targets have varied in di...

متن کامل

Evaluation of dose distribution of 12C ion beam in radiotherapy by FLUKA as a Monte Carlo simulation Code

Introduction: Nowadays, the use of heavy ion beams in cancer therapy have been developed worldwide.   Materials and Methods: It requires accurate understanding of the complex processes of ion interaction with matter, as it is the calculation the relative dose & range of these ions in matter. In the present study we used FLUKA as a numerical Monte Carlo simula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011