Resolution recovery in Turbo Spin Echo using segmented Half Fourier acquisition.

نویسندگان

  • Cristina Santa-Marta
  • Javier Lafuente
  • Juan José Vaquero
  • Pedro Garcia-Barreno
  • Manuel Desco
چکیده

Turbo Spin Echo (TSE) is a sequence of choice for obtaining T(2)-weighted images. TSE reduces acquisition time by acquiring several echoes within each TR, at the cost of introducing an exponential weighting in the k-space that leads to a certain image blurring. This is particularly important for short-T(2) structures, which can even disappear if their size in the phase encoding direction is comparable to the degree of blurring. This article suggests the use of a combination of Half Fourier (HF) and segmented (multishot) TSE (sHF-TSE) to recover the original resolution of the SE images. The improved symmetry of the dataset achieved by HF reconstruction is used to increase the resolution of the TSE images. The proposed combination, available in most clinical scanners, reduces the blurring artifact inherent to the TSE sequence without increasing the scan time or the number of acquisitions, but at the cost of a slight reduction of the signal-to-noise ratios (SNR). Qualitative and quantitative results are presented using both numerical simulation and imaging. Significant edge enhancement has been achieved for structures with short T(2), (narrowing of the full width at half maximum [FWHM] up to 45%). The proposed sequence is more sensitive to movement artifacts but has proven to be superior to the conventional TSE for imaging static structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Most commonly used sequences and clinical protocols for brain and spine magnetic resonance imaging allowing better identification of pathological changes in dogs.

Magnetic resonance imaging is the best imaging modality for the brain and spine. Quality of the received images depends on many technical factors. The most significant factors are: positioning the patient, proper coil selection, selection of appropriate sequences and image planes. The present contrast between different tissues provides an opportunity to diagnose various lesions. In many clinics...

متن کامل

MR sialography using half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences.

We describe our preliminary experience with the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences for MR imaging of the salivary gland ducts. In the majority of patients, the main parotid and/or submandibular gland ducts and large branches within the glands were detectable on MR images obtained in 2 seconds per section and within 3 minutes for the entire examination. MR sia...

متن کامل

MR Urography in Patients with Acute Flank Pain: Comparison of Gadolinium-Enhanced 3D FLASH After Low-Dose Diuretic with 2D Turbo Spin Echo Sequences

Introduction: Intravenous excretory urography (IVU) has been regarded as the imaging modality of choice for the detection of urinary tract disorders in patients with acute flank pain. Functional as well as anatomical details are provided by this imaging technique. The use of ionised radiation and contrast material (CM) are considered to be the major drawbacks of IVU. Recently, the use of magnet...

متن کامل

Half-fourier acquisition single-shot turbo spin-echo (HASTE) MR: comparison with fast spin-echo MR in diseases of the brain.

PURPOSE To compare an ultrafast T2-weighted (half-Fourier acquisition single-shot turbo spin-echo [HASTE]) pulse sequence with fast spin-echo T2-weighted sequences in MR imaging of brain lesions. METHODS Fast spin-echo and HASTE images of 34 consecutive patients over the age of 50 years or with suspected demyelinating disease were reviewed independently by two neuroradiologists for the number...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 22 3  شماره 

صفحات  -

تاریخ انتشار 2004