Corneal and total optical aberrations in a unilateral aphakic patient.

نویسندگان

  • Sergio Barbero
  • Susana Marcos
  • Jesús Merayo-Lloves
چکیده

PURPOSE To measure corneal and total optical aberrations in the normal and treated eye of a unilateral aphakic patient to (1) cross-validate techniques in an eye in which corneal and total aberrations should be almost identical (aphakic eye) and (2) compare the interactions of corneal and internal aberrations in the normal eye with those in the aphakic eye. SETTING Instituto de Optica, Consejo Superior de Investigaciones Científicas, Madrid, Spain. METHODS Aberrations in both eyes of a unilateral aphakic patient were measured using laser ray tracing. Corneal aberrations were obtained from corneal elevation data measured with a corneal videokeratoscope (Humphrey Instruments) using custom software that performs virtual ray tracing on the measured front corneal surface. RESULTS There was a 98.4% correspondence between the total and corneal aberration pattern in the aphakic eye (6.5 mm pupil). In the normal eye, the total spherical aberration was much lower than the corneal spherical aberration; this did not occur in the aphakic eye. CONCLUSIONS The posterior corneal surface contributed slightly to the aberrations in the normal cornea (2% at most). The crystalline lens appears to play a compensatory role in the total spherical aberration in normal eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Objective assessment of the quality of vision before and after repositioning of a dislocated iris-fixated aphakic anterior chamber lens.

PURPOSE To document severe visual symptoms due to the dislocation of an iris-fixated aphakic anterior chamber lens using wavefront aberrometry. METHODS A patient complaining of severe visual blur and distortion due to a decentered Artisan iris-fixated anterior chamber lens was evaluated pre- and postoperatively after recentration. The patient underwent complete ophthalmic evaluation including...

متن کامل

Validation of the estimation of corneal aberrations from videokeratography in keratoconus.

PURPOSE To validate the estimation of corneal aberrations from videokeratography against a laser ray tracing technique that measured total eye aberrations, in eyes without keratoconus (ie, cornea-dominated wave aberrations). METHODS We measured total and corneal wave aberrations of three eyes diagnosed with keratoconus by slit-lamp microscopy and corneal topography: two eyes from one patient ...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Corneal Changes in Children after Unilateral Cataract Surgery in the Infant Aphakia Treatment Study.

PURPOSE We report endothelial cell (EC) characteristics and central corneal thickness (CCT) from the Infant Aphakia Treatment Study (IATS) patients at the 5-year examination. DESIGN Randomized, controlled trial of the treatment of unilateral cataract with aphakic contact lens (CL) versus primary intraocular lens (IOL) implant. PARTICIPANTS A total of 114 infants with unilateral cataract. ...

متن کامل

Optical response to LASIK surgery for myopia from total and corneal aberration measurements.

PURPOSE To evaluate the optical aberrations induced by LASIK refractive surgery for myopia on the anterior surface of the cornea and the entire optical system of the eye. METHODS Total and corneal aberrations were measured in a group of 14 eyes (preoperative myopia ranging from -2.5 to -13 D) before and after LASIK surgery. Total aberrations were measured using a laser ray-tracing technique. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 28 9  شماره 

صفحات  -

تاریخ انتشار 2002