A novel subcutaneous T-shaped bridge device for loop colostomies.

نویسندگان

  • José Joaquim Ribeiro da Rocha
  • Marley Ribeiro Feitosa
  • Thiago Rodrigues da Cunha Stoianov
  • Camila Perazzoli
  • Vanessa Foresto Machado
  • Mário Vinícius Angelete Alvarez Bernardes
  • Rogério Serafim Parra
  • Omar Féres
چکیده

PURPOSE To describe a novel securing device for loop colostomies, developed in our institution and report our 10-year experience. METHODS The T-shaped support device was used in all patients who required loop colostomy and who were at an increased risk of stoma withdrawal. The device was removed on the fifth postoperative day in all patients. An analysis from a prospective database regarding early postoperative complication, from 209 patients, was conducted between 2003 and 2013. RESULTS Bleeding, peristomal skin problems, surgical site infection, stomal ischemia/necrosis, stenosis, obstruction, retraction and early withdrawal of the stoma were not noted in all cases. Thirteen patients (6%) reported mild discomfort on the site of the skin suture. Removal of the instrument was fast and easy, with the advantage of keeping the colostomy bag. CONCLUSION The T-shaped bridge device successfully prevented stoma withdrawal in all subjects. The device was safe and well accepted, with minor complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AN EASY SOLUTION FOR THE DIVERTING LOOP COLOSTOMY: OUR TECHNIQUE

 ABSTRACT Background: The loop colostomy is one of the most popular techniques used as a protective maneuver for a distal anastomosis and/or temporary fecal diversion. We are introducing the use of a full thickness skin bridge under the large bowel instead of a glass rod which alleviates problems such as protrusion of the large bowel, retraction of the bowel into the abdomen after removing the ...

متن کامل

[Morbidity and mortality associated to loop colostomy and ileostomy closure].

OBJECTIVE To evaluate the morbidity and mortality of operations for closure of loop colostomies and ileostomies. METHODS We analyzed epidemiological data, postoperative complications, morbidity and mortality of patients who underwent operations for closure of loop colostomies and ileostomies. We excluded patients whose data could not be obtained from the files and operations that required lap...

متن کامل

Simulation and Experimental Verification of Closed Loop Operation of Buck / Boost DC-DC Converter with Soft Switching

A major problem in an isolated DC/DC converters operating at high switching frequencies is the attendant switching losses in the semiconductor devices. This can be reduced by introducing either zero-voltage switching (ZVS) or zero-current switching (ZCS) of the semiconductor switches. This paper deals with the simulation, design, fabrication and experimental evaluation of a novel soft-switching...

متن کامل

Low Settling Time All Digital DLL For VHF Application

Settling time is one of the most important parameter in design of DLLs. In this paper we propose a new high speed with low settling time Delay Locked Loop (DLL) in which a digital signal processor (DSP) is used instead of using phase-frequency detector, charge pump and loop filter in conventional DLL. To have better settling time, PRP conjugate gradient algorithm is used to optimize delay of ea...

متن کامل

Detecting System Design of Bridge Cables

In this paper, we designed a new detecting system of bridge cables with a snake-shaped robot. It can solve the problems such as inefficiency and danger of aloft work in the bridge detecting by workers. The detecting system of the bridge cables includes: a snake-shaped robot; a multiple and monocular vision detection module; a nondestructive magnetic leakage detecting module; a magnetostrictive ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta cirurgica brasileira

دوره 31 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2016