High-flow carotid cavernous fistula and the use of a microvascular plug system: initial experience.

نویسندگان

  • Yamin Shwe
  • Srinivasan Paramasivam
  • Santiago Ortega-Gutierrez
  • David Altschul
  • Alejandro Berenstein
  • Johanna T Fifi
چکیده

PURPOSE We report our initial experience using a detachable microvascular plug system to occlude the internal carotid artery during endovascular treatment of high-flow carotid cavernous fistula. CASE AND TECHNIQUE An 87-year-old patient was admitted for acute-onset double vision with associated right-eye ptosis. Exam revealed a pupil-sparing, partial right third cranial nerve palsy. MRI showed a carotid cavernous fistula with high-flow drainage. Digital subtraction angiography showed a high-flow, right-sided, direct carotid cavernous fistula with flow from the proximal right internal carotid artery. The ophthalmic artery, posterior communicating artery and anterior communicating arteries supplied retrograde flow to the fistula through the internal carotid artery. Obliteration of the fistula was achieved through coil embolization in combination with proximal and distal microvascular plugs (Reverse Medical, Irvine, Calif., USA). CONCLUSION The microvascular plug is a new addition to current endovascular embolization devices for the treatment of high-flow, direct carotid cavernous fistulas. This technique offers easy navigability through tortuous arteries, precise localization and immediate occlusion, which may allow shorter procedure and fluoroscopy times and increased cost-effectiveness. Larger case series are needed to support our observation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Endovascular treatment of carotid-cavernous fistula type A with platinium coils].

BACKGROUND Carotid-cavernous fistulas are abnormal communications between carotid arteries or their branches and the cavernous system caused mostly by trauma. Posttraumatic fistulas represent 70% of all carotid-cavernous fistulas and they are mostly high-flow shunts (type A). This type gives characteristic eye symptoms. CASE REPORT This paper presents a 44-year old male patient with carotid-c...

متن کامل

Spontaneous resolution of a trauma induced direct carotid cavernous fistula

Introduction: Direct carotid cavernous fistulas (CCF) are abnormal communications between the internal carotid artery and the cavernous sinus usually resulting from high energy trauma to the face and base of skull. The management of direct CCF relies on endovascular procedures repairing the malformation as healing cannot take place in the high flow system. Case Report: A 16­year­old male presen...

متن کامل

[Use of detachable balloon catheters in the treatment of carotid-cavernous fistula].

A new flexible detachable balloon apparatus has been developed. It consists of three parts; a silicone balloon, a teflon introducing catheter, and stainless steel coaxial catheter. A coaxial catheter with a stainless steel tubular spring is used to afford a higher degree of flexibility for better naviga tion in the various angulations of the intracranial vasculature. A miter valve is used as a ...

متن کامل

Endovascular treatment of high-flow carotid cavernous fistulas by stent-assisted coil placement.

BACKGROUND AND PURPOSE Endovascular techniques are the methods of choice for the treatment of patients with carotid cavernous fistulas. We report our experience using stent-assisted coil placement for treatment of patients with high-flow fistulas that are associated with severe laceration of the internal carotid artery. METHODS In a retrospective review of an internal endovascular therapy dat...

متن کامل

Transarterial Treatment of Direct Carotid Cavernous Fistulas with the Assistance of Undetachable Balloons

Directed carotid cavernous fistula means high blood flow shunts between the internal carotid artery and the cavernous sinus. Obstructing the abnormal shunt between the internal carotid artery and the cavernous sinus while preserving the internal carotid artery is the key role in fistula treatment. Transarterial balloon embolization is currently the gold standard treatment for most of the caroti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Interventional neurology

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 2015