چکیده
For the submillimeter band observations, we have been routinely adopting the calibration cycle time of 20–30 minutes, which is the same as any typical centimeter and millimeter band observations. This cycle time, largely corrects only the instrumental phase fluctuations and there exists residual phase fluctuations, which are attributed to temporal and spatial atmospheric phase fluctuations. Hence, the classical calibration cycle needs closer attention for any future submillimeter band observations. We have therefore obtained fast-switching test data, cycling between three nearby calibrators, using the submillimeter array (SMA) with a cycle time of ∼90 sec, in order to understand and optimize the calibration cycle suitably, thereby to achieve the projected sensitivity, angular resolution and dynamic range for the SMA. Here, we present the preliminary results from this study.
منابع مشابه
Atmospheric Phase Correction Using Total Power Radiometry at the Submillimeter Array
Phase noise caused by an inhomogeneous, time-variable water vapor distribution in our atmosphere reduces the angular resolution, visibility amplitude and coherence time of millimeter and submillimeter wavelength interferometers. We present early results from our total power radiometry phase correction experiment carried out with the Submillimeter Array on Mauna Kea. From accurate measurements o...
متن کاملLarge-eddy simulation of turbulent flow over an array of wall-mounted cubes submerged in an emulated atmospheric boundary-layer
Turbulent flow over an array of wall-mounted cubic obstacles has been numerically investigated using large-eddy simulation. The simulations have been performed using high-performance computations with local cluster systems. The array of cubes are fully submerged in a simulated deep rough-wall atmospheric boundary-layer with high turbulence intensity characteristics of environmental turbulent fl...
متن کاملSimulating Atmospheric Phase Errors, Phase Correction and the Impact on ALMA Science
We present a framework for modelling atmospheric phase errors and their correction by both the fast-switching and water vapour radiometeric techniques. Notable features are simulating three dimensional turbulent volumes instead of flat phase screens, considering three representative configurations of ALMA and parametrisation in terms of phase fluctuations on a 300m baseline, allowing referencin...
متن کاملFTS Measurements of Submillimeter-Wave Atmospheric Opacity at Pampa la Bola III. Water Vapor, Liquid Water, and 183 GHz Water Vapor Line Opacities
Further analysis has been made on the millimeter and submillimeter-wave (100–1600 GHz or 3 mm – 188 μm) atmospheric opacity data taken with the Fourier Transform Spectrometer (FTS) at Pampa la Bola, 4800 m above sea level in northern Chile, which is the site of the Atacama Large Millimeter/submillimeter Array (ALMA). Time-sequence plots of millimeter and submillimeter-wave opacities show simila...
متن کاملALMA Memo 415 Phase Correction using Submillimeter Atmospheric Continuum Emission
We discuss a phase correction method using total power from submillimeter/millimeter SIS receivers. The discussion is based on FTS measurements and model calculations of submillimeter/millimeter atmospheric emission under various weather conditions. Liquid water in the atmosphere (cloud or fog) limits the phase correction accuracy using the total power measurements. Comparison between millimete...