Part I Flow Quantification of the Mitral Valve: Combining Phase Contrast with Ssfp
نویسندگان
چکیده
Multiecho phase-contrast steady-state free precession (PC-SSFP) is a recently introduced sequence for flow quantification. In this multiecho approach, a phase reference and a velocity-encoded readout were acquired at different echo times after a single excitation. In this study, the sequence is validated in vitro for stationary flow. Subsequently, the sequence was evaluated on cardiac output measurements in vivo for throughplane flow in comparison to regular single gradient echo velocity quantification [phase-contrast spoiled gradient echo (PC-GE)]. In vitro results agreed with regular flow meters (RMS 0.1 cm/s). Cardiac output measurements with multiecho PC-SSFP on 10 healthy subjects gave on average the same results as the standard PC-GE. However, the limits of repeatability of PC-SSFP were significantly larger than those of PC-GE (2 l/min and 0.5 l/min, respectively, P=0.001). The multiecho approach introduced some specific problems in vivo. The difference in echo times made the velocity maps sensitive for waterfat shifts and B0-drifts, which in turn made velocity offset correction problematic. Also, the addition of a single bipolar gradient cancelled the flow compensated nature of the SSFP sequence. In combination with the prolonged TR, this resulted in flow artifacts caused by high and pulsatile through-plane flow, affecting repeatability. Given the significantly lower repeatability of PC-SSFP, cardiac output in turn is less reliable, thus impairing the use of multiecho PC-SSFP. 2.
منابع مشابه
Mitral valve blood flow quantification by 7D phase contrast SSFP - a feasibility study
Purpose: to assess the feasibility of a new 7D PC-SSFP sequence for single acquisition mitral regurgitation volume quantification. Materials and Methods: The 7D PC-SSFP sequence implementation is based on a regular 3D balanced SSFP gradient scheme with velocity encoding. Accuracy of velocity quantification was confirmed using a flow-phantom. Mitral volume flow was measured in ten healthy subjec...
متن کاملFlow quantification in the heart chambers: 3D PC-SSFP compared with spoiled GE
Introduction: Flow quantification through the valves is of major importance in patients with valvular heart disease. Using a 3D MRI acquisition, the mitral valve can be imaged during the whole cardiac cycle, for direct quantification of flow through the valve. So far, 3D phase contrast (PC) for velocity quantification is only implemented in a spoiled Gradient Echo (GE) sequence. However, PC-GE ...
متن کامل3D velocity quantification in the heart: improvements by 3D PC-SSFP.
PURPOSE To test whether a 3D imaging sequence with phase contrast (PC) velocity encoding based on steady-state free precession (SSFP) improves 3D velocity quantification in the heart compared to the currently available gradient echo (GE) approach. MATERIALS AND METHODS The 3D PC-SSFP sequence with 1D velocity encoding was compared at the mitral valve in 12 healthy subjects with 3D PC-GE at 1....
متن کاملSummary and General Discussion
The research described in this thesis was aimed at improving velocity measurements of blood flow in the ventricles using cardiac Magnetic Resonance Imaging. The incentive for this work was the clinical need to quantify the severity of mitral valve regurgitation in an absolute sense. MRI is an important non-invasive diagnostic tool in cardiology. Besides imaging the anatomy, the MR phase contras...
متن کاملCardiovascular magnetic resonance evaluation of left ventricular peak filling rate using steady-state free precession and phase contrast sequences
BACKGROUND We investigated a practical method to measure peak filling rate (PFR) as an indicator of diastolic function of the left ventricle. Ten adult volunteers underwent cine MR imaging using steady-state free precession (SSFP) and phase contrast (PC) sequences to measure PFR. Two PC image sets were acquired at the mitral valve orifice, and PFR was determined from the set with high true temp...