OBJECTIVE Point-of-care testing (POCT) urinalysis might reduce errors in (subjective) reading, registration and communication of test results, and might also improve diagnostic outcome and optimise patient management. Evidence is lacking. In the present study, we have studied the analytical performance of automated urinalysis and visual urinalysis compared with a reference standard in routine general practice. SETTING The study was performed in six general practitioner (GP) group practices in the Netherlands. Automated urinalysis was compared with visual urinalysis in these practices. Reference testing was performed in a primary care laboratory (Saltro, Utrecht, The Netherlands). PRIMARY AND SECONDARY OUTCOME MEASURES Analytical performance of automated and visual urinalysis compared with the reference laboratory method was the primary outcome measure, analysed by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and Cohen's κ coefficient for agreement. Secondary outcome measure was the user-friendliness of the POCT analyser. RESULTS Automated urinalysis by experienced and routinely trained practice assistants in general practice performs as good as visual urinalysis for nitrite, leucocytes and erythrocytes. Agreement for nitrite is high for automated and visual urinalysis. κ's are 0.824 and 0.803 (ranked as very good and good, respectively). Agreement with the central laboratory reference standard for automated and visual urinalysis for leucocytes is rather poor (0.256 for POCT and 0.197 for visual, respectively, ranked as fair and poor). κ's for erythrocytes are higher: 0.517 (automated) and 0.416 (visual), both ranked as moderate. The Urisys 1100 analyser was easy to use and considered to be not prone to flaws. CONCLUSIONS Automated urinalysis performed as good as traditional visual urinalysis on reading of nitrite, leucocytes and erythrocytes in routine general practice. Implementation of automated urinalysis in general practice is justified as automation is expected to reduce human errors in patient identification and transcribing of results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Study of Psychotropic Drugs Being Prescribed to the Patients Attending the Psychiatric Outpatient Department in a Tertiary Care Hospital

BACKGROUND & PURPOSE: Drug utilization research evaluates the appropriateness of the prescriptions which is important in clinical practice. Psychotropic polypharmacy is a major problem in psychiatric practice, which can lead to the development of adverse effects of those drugs in patients. Therefore, this study was carried out to evaluate the utilization of psychotropic drugs being prescribed f...

متن کامل

Current practice of percutaneous coronary intervention on patients with acute coronary syndrome in Iran: A prospective observational study

Background: Frequent Percutaneous Coronary Intervention (PCI) procedures are being performed on a daily basis in Iran. However, no study has been reported on the current PCI practice in patients with acute coronary syndrome (ACS) in Iran. We aimed to describe the clinical characteristics and treatment patterns in Iranian ACS patients treated with PCI.    Methods: Between February 2017 and July...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

FAST and abnormal urinalysis: the effective screening tools in pediatric abdominal trauma

Objective: The present study examines the diagnostic accuracy of abdominal ultrasonography and urinalysis test in children with blunt abdominal trauma, compared with CT scan. The aim of this study was to compare the diagnostic value of ultrasound and urinalysis test with CT scan as a golden standard diagnostic method in predicting abdominal peritoneal injury in these patients.Methods: Thi...

متن کامل

Prescribing Pattern of Psychotropic Medications in Psychiatry Outpatients at a Tertiary Care Teaching Hospital in India: A Prospective Cross-sectional Study

Background and Objectives: The expanding field of psychopharmacology is constantly seeking new and improved drugs to treat psychiatric disorders. Although psychotropic drugs have had a remarkable impact in psychiatry, their utilization, effectiveness, and side effects in the in clinical practice need continuous study. The present study was thus designed to analyze the pattern of psychotropic dr...