Monitoring equipment induced tachycardia in patients with minute ventilation rate-responsive pacemakers.

نویسندگان

  • P A Southorn
  • G S Kamath
  • G M Vasdev
  • D L Hayes
چکیده

Minute ventilation-sensing pacemakers enable the paced heart to respond to an increased workload. Two patients with such a pacemaker developed pacemaker-driven tachycardia when connected to an electrocardiogram (ECG) monitor also capable of documenting ventilatory frequency and ECG lead disconnection. This tachycardia stopped when the ECG leads were removed. These pacemakers and monitors emit a low-amplitude electrical current and measure the resultant impedence signal across the chest. When patients are connected to the monitor the pacemaker sensor summates both impedence signals and the paced heart rate is increased as a result.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker-induced tachycardia during general anaesthesia: a case report.

Pacemakers with a rate-responsive function, based on calculation of ventilatory minute volume, may induce tachycardia in patients who undergo hyperventilation during general anaesthesia. If hyperventilation is desired, it is recommended that the pacemaker is reprogrammed in order to avoid tachycardia. If the programming device is not available, a magnet may be placed over the pacemaker site to ...

متن کامل

Usefulness of Hemodynamic Sensors for Physiologic Cardiac Pacing in Heart Failure Patients

The rate adaptive sensors applied to cardiac pacing should respond as promptly as the normal sinus node with an highly specific and sensitive detection of the need of increasing heart rate. Sensors operating alone may not provide optimal heart responsiveness: central venous pH sensing, variations in the oxygen content of mixed venous blood, QT interval, breathing rate and pulmonary minute venti...

متن کامل

Electrocardiogram artefacts caused by an abdominal electrostimulator.

A 74-year-old woman presented to hospital with dyspnoea of sudden onset. She was in cardiogenic shock, with blood pressure of 90/50 mmHg, and pulse rate of 115 bpm. The electrocardio-gram (ECG) was difficult to interpret because of severe, persistent and inexplicable artefacts (Box 1A). Chest x-ray showed acute pulmonary oedema thought secondary to left ventricular failure. Echocardiography sho...

متن کامل

Comparison of the normal sinus node with seven types of rate responsive pacemaker during everyday activity.

The heart rate response of 59 patients aged 17-79 years implanted with seven different types of rate responsive pacemakers was evaluated during graded exercise treadmill testing and during standardised daily activities. The heart rate response in patients with pacemakers was compared with the chronotropic response in 20 healthy controls of similar age and sex distribution who performed identica...

متن کامل

Importance of maintained atrio-ventricular synchrony in patients with pacemakers.

The effect of atrial contraction on cardiac function is reviewed in patients with dual chamber and rate-responsive ventricular pacemakers. The question posed was is there any haemodynamic, clinical or prognostic advantage of AV synchrony in dual chamber pacemakers in comparison to rate-responsive ventricular pacemakers? Optimal AV delay in dual chamber pacing favours cardiac performance at rest...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 84 4  شماره 

صفحات  -

تاریخ انتشار 2000