Analysis of urinary stone components by x-ray coherent scatter: characterizing composition beyond laboratory x-ray diffractometry.

نویسندگان

  • Melanie T M Davidson
  • Deidre L Batchelar
  • Sujeevan Velupillai
  • John D Denstedt
  • Ian A Cunningham
چکیده

Monoenergetic x-ray diffraction (XRD) analysis is an established standard for the assessment of urinary stone composition. The inherent low energy of x-rays used (8 keV), however, restricts penetration depth and imposes a requirement for small powdered samples. A technique capable of producing detailed information regarding component structural arrangements in calculi non-destructively would provide clearer insights into causes of formation and subsequent growth and allow the selection of more appropriate courses of therapy. We describe a new method based on the detection of coherent scatter (CS) in stone components using polyenergetic x-rays (70 kVp) from diagnostic equipment. While the higher energy allows the analysis of intact calculi, the polyenergetic source causes an angular broadening of measured CS patterns. We show that it is possible to relate the polyenergetic (CS) and monoenergetic (XRD) measurements through a superposition integral of the monoenergetic XRD cross-section with a function representative of the polyenergetic spectrum used in CS. Experimentally acquired diffractometry cross-sections of the seven major urinary stone components were subjected to this operation, revealing good agreement of diffraction features with CS. Therefore, our CS analysis is sensitive to stone component structure, similar to conventional XRD analysis. This indicates that CS analysis can be used as a basis to classify urinary calculi by composition. The potential of identifying stone components non-destructively was demonstrated from a tomographic CS analysis of a stone-mimicking phantom. Tomographic composition maps were generated from CS patterns, showing the structural arrangement of multiple stone components within the phantom. CS analysis has the ability to detect components in the presence of many others. The ability to perform CS measurements in intact calculi would allow for the identification of stone structures critical to patient metaprophylaxis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Establishing composition and structure of intact urinary calculi by x-ray coherent scatter for clinical laboratory investigations.

PURPOSE Current urinary stone analysis techniques are limited in their abilities to simultaneously characterize composition and structure. Laboratory techniques such as IRS and x-ray diffractometry require small powdered samples for analysis, rendering composition results dependent on the choice of sample and its preparation. We investigated the application of x-ray CS analysis to identify topo...

متن کامل

Kidney stone analysis by x-ray coherent scatter: new insights for therapy?

The success of medical therapies may depend on the type of stone. Knowledge of stone composition often dictates the course of treatment followed by the urologist [5,8]. It can shed some light on the nature of stone formation and identify metabolic abnormalities and underlying medical conditions [9]. Stone composition may thus provide the critical insights needed to devise targeted preventative ...

متن کامل

Introducing an Optimized Method for Obtaining X-ray Diffraction Patterns of Biological Tissues

Introduction Individual X-Ray diffraction patterns of biological tissues are obtained via interference of coherent scattering with their electrons. Many scientists have distinguished normal and cancerous breast tissue, bone density, and urinary stone types using the X-Ray diffraction patterns resulting from coherent scattering. The goal of this study was to introduce an optimized method for obt...

متن کامل

A CMOS active pixel sensor system for laboratory- based x-ray diffraction studies of biological tissue.

X-ray diffraction studies give material-specific information about biological tissue. Ideally, a large area, low noise, wide dynamic range digital x-ray detector is required for laboratory-based x-ray diffraction studies. The goal of this work is to introduce a novel imaging technology, the CMOS active pixel sensor (APS) that has the potential to fulfil all these requirements, and demonstrate i...

متن کامل

Quality Assessment of Urinary Stone Analysis: Results of a Multicenter Study of Laboratories in Europe

After stone removal, accurate analysis of urinary stone composition is the most crucial laboratory diagnostic procedure for the treatment and recurrence prevention in the stone-forming patient. The most common techniques for routine analysis of stones are infrared spectroscopy, X-ray diffraction and chemical analysis. The aim of the present study was to assess the quality of urinary stone analy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 50 16  شماره 

صفحات  -

تاریخ انتشار 2005