A physician's office-based digoxin assay (Seralyzer) evaluated for interference by endogenous digoxin-like immunoreactive factors.

نویسندگان

  • M L Matheke
  • R Valdes
چکیده

A digoxin test for a physician's office based-chemistry analyzer (Ames Seralyzer) was evaluated for possible interference by digoxin-like immunoreactive factors (DLIF). Sera from patients likely to have high concentrations of DLIF (renal and hepatic patients, pregnant women, and neonates) as well as from normal patients and umbilical cord blood were analysed by the Seralyzer digoxin immunoassay and by a fluorescence polarization digoxin immunoassay (Abbott TDx) known to detect DLIF. For all patients who were not taking digoxin (n = 85) only four patients (4.7 percent) measured apparent digoxin values greater than 0.2 ng per mL by the Seralyzer compared to 64 (75 percent) by the TDx analyzer. Measurements of DLIF from adrenal extracts demonstrated a 17-fold greater potency for detection of DLIF by the TDx (2.9 ng per mL) compared to the Seralyzer technique (0.18 ng per mL). However, recovery data suggest that the presence of digoxin reduces the potency of DLIF interference as a function of increasing digoxin concentrations especially for the TDx assay. This diminished DLIF crossreactivity in the presence of digoxin is one explanation for the comparable correlation observed for both non-renal and renal failure patients taking digoxin when measured by these two immunoassays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endogenous digoxin-like immunoreactive factors eliminated from serum samples by hydrophobic silica-gel extraction and enzyme immunoassay.

Elimination of endogenous digoxin-like immunoreactive factors (DLIF) that interfere with accurate measurement of digoxin requires use of a highly specific anti-digoxin antibody, or that DLIF be separated from digoxin before immunoassay. Several commercial digoxin-assay kits include a step for separating serum proteins and other substances from digoxin before immunoassay. We tested six different...

متن کامل

Methods for eliminating interferences in digoxin immunoassays caused by digoxin-like factors.

Endogenous, circulating digoxin-like immunoreactive factors (DLIF) are known to cross react with many antisera used in digoxin assays, complicating the quantification of serum digoxin. We have explored ways to decrease or remove the interference from DLIF in such assays. Prolonging the assay incubation from 30 to 60 min decreased apparent digoxin concentrations (attributable to DLIF) by an aver...

متن کامل

Vitros digoxin immunoassay evaluated for interference by digoxin-like immunoreactive factors.

by Digoxin-like Immunoreactive Factors, Barbara A. Way, Timothy R. Wilhite, Ralph Miller, Carl H. Smith, and Michael Landt (Departments of 1 Pediatrics and 2 Pathology, Washington University School of Medicine, St. Louis Children’s Hospital, and 3 BJC Health System, St. Louis, MO 63110; * author for correspondence: Department of Pediatrics, Washington University School of Medicine, St. Louis Ch...

متن کامل

Improved interassay correlation of digoxin results in patients with and without renal failure by elimination of digoxin-like immunoreactive factors.

Use of immunoassays that do not detect endogenous digoxin-like immunoreactive factors (DLIF) in serum significantly improves the between-assay correlation of digoxin results for patients. We investigated five different immunoassay methods (Abbott, Clinical Assays, Corning, Du Pont, and Syva), measuring digoxin by all five assays in sera from 38 patients in renal failure and in 40 patients with ...

متن کامل

The fractional error as a means of assessing agreement between two methods measuring the same variable.

During the past 15 years, digoxin has been routinely measured in serum by various immunoassays. Unfortunately, all of the currently available immunoassays exhibit various cross reactivities with drugs, digoxin metabolites, and endogenous digoxin-like immunoreactive substances (1, 2). We recently encountered several patients for whom we were unable to obtain a reportable digoxin concentration wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 1989