Comparison of Doses to Normal Brain in Patients Treated With Boron Neutron Capture

نویسندگان

  • Julie Catherine Turcotte
  • Jeffrey A. Coderre
  • Jeffrey Coderre
چکیده

A number of boron neutron capture therapy (BNCT) clinical trials are currently underway around the world. Due to the small number of patients at each of the individual centers, it is desirable to pool the clinical data from each into one patient database. Before this can be done, a number of differences between the clinical centers must be evaluated. The patients treated at the BNCT centers at Brookhaven National Laboratory and that at Harvard-MIT will be evaluated as a start to the ultimate pooling of all the BNCT centers. One difference involves the difference between the normal tissue composition definition between the institutions. In particular, the difference in weight percent of 4N must be evaluated. This particular component of tissue is of importance due to the dose to tissue resulting from the 4N(n,p)l C reaction. The difference between the 1.8% '4N composition used at BNL and the 2.2% used at MIT has a negligible effect on the total dose. Most importantly, differences in dosimetry techniques between the different centers must be computed. Once these differences are quantified, the patients can be pooled, and a better estimate of the normal brain tolerance to BNCT can be determined. The thermal neutron doses calculated from thermal flux measurements are 8% lower when measured by MIT, the gamma dose measurements are 26% lower, and the in-air fast neutron measurements are 27% lower in the same beam. The endpoint used for the tolerance of normal brain to BNCT is somnolence syndrome. A 50% somnolence response can be seen at 5.5 Gy-Eq. Thesis Supervisor: Jeffrey A. Coderre Title: Associate Professor of Nuclear Engineering and Rasmussen Professor of Nuclear Engineering

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

متن کامل

Dosimetry Impact of Boron and Its Carriers Structure at Boron Neutron Capture Therapy of a Brain Tumor; A Sim- ulation Study

Introduction: Boron neutron capture therapy (BNCT) is a method of cancer treatment and potentially, two borono-L-phenylalanine (BPA) and sodium borocaptate (BSH) are used in BNCT as common boron carriers. Some previous studies have shown that the dose rate is directly related to boron concentration in the tissue. This study aimed to simulate the structure of boron carriers and brain tumor compo...

متن کامل

Dosimetry Impact of Boron and Its Carriers Structure at Boron Neutron Capture Therapy of a Brain Tumor; A Sim- ulation Study

Introduction: Boron neutron capture therapy (BNCT) is a method of cancer treatment and potentially, two borono-L-phenylalanine (BPA) and sodium borocaptate (BSH) are used in BNCT as common boron carriers. Some previous studies have shown that the dose rate is directly related to boron concentration in the tissue. This study aimed to simulate the structure of boron carriers and brain tumor compo...

متن کامل

A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom

Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...

متن کامل

Investigation the potential of Boron neutron capture therapy (BNCT) to treat the lung cancer

Introduction: Boron neutron capture therapy (BNCT) is recommended to treat the glioblastoma tumor. It is well known that neuron beams are more effective treatment than photon beams to treat hypoxia tumors due to interaction of neutron with nucleus and production of heavy particles such as 7Li and alpha particle. In this study to evaluate the suitability of BNCT for treating of ...

متن کامل

An Introduction to Boron Neutron Therapy (BNCT): Current Status and Future Outlook

Boron neutron capture therapy (BNCT) is based on the nuclear reaction, such that B-10 irradiated with low-energy thermal neutrons produces alpha particles with high linear energy transfer and lithium-7. Clinically, BNCT is used primarily for treatment of high-grade glioma or brain metastases from melanoma and, more recently, head, neck and liver cancers. Since reactors have long been used to pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006