Sample preparation and liquid-chromatographic analysis for tricyclic antidepressants in serum.
نویسندگان
چکیده
We report two separate sample-preparation procedures and a "high-pressure" liquid-chromatographic method for quantitating nine tricyclic antidepressant drugs: trimipramine, doxepin, amitriptyline, imipramine, desmethyldoxepin, nortriptyline, desipramine, maprotiline, and protriptyline. The drugs are extracted from 1 mL of serum by a single manual hexane extraction or by using DuPont's PREP I Automated Sample Processor. The drugs from either process are chromatographed on a mu-Bondapak-CN column with a mobile phase of acetonitrile/methanol/Na2HPO4, 5 mmol/L (60/15/25 by vol), pH 7.0, at a flow rate of 2.0 mL/min. Absorbance at 254 nm is linear with drug concentration from 25 to 1000 mg/L for each drug. With the manual extraction procedure the detection limit was 10 mg/L, absolute recovery 20-44%, within-run precision (CV) 10.1%, and run-to-run precision 11.1%. The performance of automated sample extraction was better, with a detection limit of 5 mg/l, absolute recovery 72-97%, within-run precision 6.1%, and run-to-run precision 6.6%.
منابع مشابه
Serum with a Single Liqui&Chromatographic Assay
CLIN. CHEM. 28/10, 2157-2160 (1982) 2. Gold, M. S., and Pottash, A. C., Depression: Diagnosis and treatment with tricyclic antidepressants. Postgrad. Med. 69, 104-117 (1981). 3. Cooper, T. B., and Kelly, R. G., GLC analysis of loxapine, amoxapine and their metabolites in seruth and urine. J. Pharm. Sci. 68, 216-219 (1979). 4. Hassan, F. M., and Ditzel; C. A., Use of high performance liquid chro...
متن کاملHIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM
A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...
متن کاملMeasurement of antidepressants by liquid chromatography: a review of current methodology.
Antidepressant measurement by liquid chromatography (LC) has enhanced the therapy of patients who are being treated with some of the first generation tricyclic antidepressants; the merits of routinely monitoring the other antidepressants await further study. Currently, the role of LC is changing from dominant to complementary as a result of the recent availability of monoclonal antibody immunoa...
متن کاملReversed-phase liquid chromatography and gas chromatography/mass fragmentography compared for determination of tricyclic antidepressant drugs.
We compare measurement of the tricyclic antidepressants desipramine, imipramine, nortryptaline, and amitryptaline by reversed-phase "high-performance" liquid chromatography and by gas chromatography/mass fragmentography. The liquid-chromatographic procedure does not require ion-pairing reagents, and involves detection at 215 nm. The within-day and between-day CVs for this method were less than ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 28 3 شماره
صفحات -