Real-Time Bladder Lesion Registration and Navigation: A Phantom Study

نویسندگان

  • Michelle Agenant
  • Herke-Jan Noordmans
  • Wim Koomen
  • J. L. H. Ruud Bosch
چکیده

BACKGROUND Bladder cancer is the fourth most common malignancy in men, with a recurrence rate of 33-64%. Tumor documentation during cystoscopy of the bladder is suboptimal and might play a role in these high recurrence rates. OBJECTIVE In this project, a bladder registration and navigation system was developed to improve bladder tumor documentation and consequently increase reproducibility of the cystoscopy. MATERIALS/METHODS The bladder registration and navigation system consists of a stereo-tracker that tracks the location of a newly developed target, which is attached to the endoscope during cystoscopy. With this information the urology registration and navigation software is able to register the 3D position of a lesion of interest. Simultaneously, the endoscopic image is captured in order to combine it with this 3D position. To enable navigation, navigational cues are displayed on the monitor, which subsequently direct the cystoscopist to the previously registered lesion. To test the system, a rigid and a flexible bladder phantom was developed. The system's robustness was tested by measuring the accuracy of registering and navigating the lesions. Different calibration procedures were compared. It was also tested whether system accuracy is limited by using a previously saved calibration, to avoid surgical delay due to calibration. Urological application was tested by comparing a rotational camera (fixed to the rotating endoscope) to a non-rotational camera (dangling by gravity) used in standard urologic practice. Finally, the influence of volume differences on registering and navigating was tested. RESULTS/CONCLUSION The bladder registration and navigation system has an acceptable accuracy for bladder lesion registration and navigation. Limitations for patient determinants included changes in bladder volume and bladder deformation. In vivo studies are required to measure the effect of these limitations and functionality in urological practice as a tool to increase reproducibility of the cystoscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary results of nonfluoroscopy-based 3D navigation for neurointerventional procedures.

PURPOSE To investigate the capabilities of a neurovascular navigation prototype in phantom experiments. MATERIALS AND METHODS The proposed navigation system integrates three-dimensional (3D) visualization of the anatomy and real-time electromagnetic localization of the endovascular tools. A 3D model of an endovascular phantom was reconstructed from thresholded preprocedural computed tomograph...

متن کامل

Comparative study of image registration techniques for bladder video-endoscopy

Bladder cancer is widely spread in the world. Many adequate diagnosis techniques exist. Video-endoscopy remains the standard clinical procedure for visual exploration of the bladder internal surface. However, videoendoscopy presents the limit that the imaged area for each image is about nearly 1 cm. And, lesions are, typically, spread over several images. The aim of this contribution is to asse...

متن کامل

Information Fusion for Real-time Motion Estimation in Image-guided Breast Biopsy Navigation

A real-time delivery of accurate soft-tissue intervention navigation information is one of the most crucial aspects for accepting the soft-tissue navigation systems for intra-operative use. Currently, soft-tissue navigation systems face some obstacles in terms of registration of the virtual navigation information on the deformable soft-tissue organ. Most of them perform a rigid registration bet...

متن کامل

Principles of Neuronavigation

Background and Aim: Numerous efforts over the past century have been performed. Various innovation techniques are increasingly gaining attention and gradually established the foundation of recent significant developments in the world of neurosurgery, among which varied stereotactic neuro-navigation designs and other novel emerging systems are being quotidian developed. This narrative review ai...

متن کامل

Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013