Accuracy of Two-Dimensional Transvaginal Sonography and Office Hysteroscopy for Detection of Uterine Abnormalities in Patients with Repeated Implantation Failures or Recurrent Pregnancy Loss

نویسندگان

  • Marzieh Shiva
  • Firouzeh Ahmadi
  • Arezoo Arabipoor
  • Mansoureh Oromiehchi
  • Mohammad Chehrazi
چکیده

Background We sought to compare diagnostic values of two-dimensional transvaginal sonography (2D TVS) and office hysteroscopy (OH) for evaluation of endometrial pathologies in cases with repeated implantation failure (RIF) or recurrent pregnancy loss (RPL). MATERIALS AND METHODS This prospective study was performed at Royan Institute from December 2013 to January 2015. TVS was performed before hysteroscopy as part of the routine diagnostic work-up in 789 patients with RIF or RPL. Uterine biopsy was performed in cases with abnormal diagnosis in TVS and/or hysteroscopy. We compared the diagnostic accuracy values of TVS in detection of uterine abnormalities with OH by receiver operating characteristic (ROC) curve analysis. RESULTS TVS examination detected 545 (69%) normal cases and 244 (31%) pathologic cases, which included 84 (10.6%) endometrial polyps, 15 (1.6%) uterine fibroids, 10 (1.3%) Asherman's syndrome, 9 (1.1%) endometrial hypertrophy, and 126 (15.9%) septate and arcuate uterus. TVS and OH concurred in 163 pathologic cases, although TVS did not detect some pathology cases (n=120). OH had 94% sensitivity, 95% specificity, 62% positive predictive value (PPV), and 99% negative predictive value (NPV) for detection of endometrial polyps. In the diagnosis of myoma, sensitivity, specificity, PPV, and NPV were 100%. TVS had a sensitivity of 50% and specificity of 98% for the diagnosis of myoma. For polyps, TVS had a sensitivity of 54% and specificity of 80%. Area under the ROC curve (AUROC) was 70.69% for the accuracy of TVS compared to OH. CONCLUSION TVS had high specificity and low sensitivity for detection of uterine pathologies in patients with RIF or RPL compared with OH. OH should be considered as a workup method prior to treatment in patients with normal TVS findings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Two-Dimensional Transvaginal Sonography and Office Hysteroscopy for Detection of Uterine Abnormalities in Patients with Repeated Implantation Failures or Recurrent Pregnancy Loss

Objective: to compare diagnostic values of two dimensional trans-vaginal sonography (TVS) and office hysteroscopy (OH) for evaluation of endometrial pathologies in cases with repeated implantation failure (RIF) or recurrent pregnancy loss (RPL). Methods and Materials: This prospective study was performed in Royan institute from December 2013 to January 2015. TVS was performed before hysteroscop...

متن کامل

I-23: The Role of Hysteroscopy in Patients with Repeated IVF Failure

The success of reproduction, although gradually increasing over the years, many couples also had been left frustrated following repeated failed attempts. Implantation of the embryo, can only take place in a receptive uterus and inadequate uterine receptivity is responsible for approximately two-thirds of implantation failures. Endometrial receptivity can be reduced by morphological and/or molec...

متن کامل

Office Hysteroscopy in Patients with Abnormal Uterine Bleeding and Normal Transvaginal Sonography

Background Abnormal uterine bleeding (AUB) is one of the most common clinical problems in gynecology. Transvaginal sonography (TVS) and hysteroscopy are two diagnostic methods for patients with AUB. For most of the patients with AUB, diagnostic hysteroscopy can be done in clinic with minimal discomfort and much lower expense than operative room. MaterialsAndMethods In our clinical trial study, ...

متن کامل

Office Hysteroscopy in Infertility

Background For patients undergoing in vitro fertilization, lower pregnancy rates are observed in the presence of uterine cavity anomalies and correction of these anomalies has been associated with improved pregnancy rates. Office hysteroscopy has been proven to have superior sensitivity and specificity in evaluation of the endometrial cavity. Diagnostic hysteroscopy can be performed in an offic...

متن کامل

I-34: Comparison between Hysteroscopy and Sonohysterography in Uterine Cavity Assessment

Intrauterine pathologies have been shown to be present in 25% of infertile patients.Structural abnormalities of the uterine endometrial cavity may affect the reproductive outcome adversely, by interfering with the implantation or causing spontaneous abortion. Intrauterine abnormalities may visualize using a variety of techniques. Including hysterosalpingography (HSG), transvaginal sonography (T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2018