Normal range of myocardial layer-specific strain using two-dimensional speckle tracking echocardiography

نویسندگان

  • Yasufumi Nagata
  • Victor Chien-Chia Wu
  • Yutaka Otsuji
  • Masaaki Takeuchi
چکیده

BACKGROUND Newer 2D strain software has a potential to assess layer-specific strain. However, normal reference values for layer-specific strain have not been established. We aimed to establish the normal ranges of layer-specific longitudinal and circumferential strain (endocardial global longitudinal strain (GLS), transmural GLS, epicardial GLS, endocardial global circumferential strain (GCS), transmural GCS, and epicardial GCS). METHODS AND RESULTS We retrospectively analyzed longitudinal and circumferential strain parameters in 235 healthy subjects, with use of layer-specific 2D speckle tracking software (GE). The endocardial strain/epicardial strain (Endo/Epi) ratio was also measured to assess the strain gradient across the myocardium. The endocardial, transmural, and epicardial GLS values and the Endo/Epi ratio in the normal subjects were -23.1±2.3, -20.0±2.0, -17.6±1.9, and 1.31±0.07, respectively. The corresponding values of GCS were -28.5±3.0, -20.8±2.3, -15.3±2.0, and 1.88±0.17, respectively. The layer-specific global strain parameters exhibited no age dependency but did exhibit gender dependency except for endocardial GCS. A subgroup analysis revealed that basal and middle levels of endocardial LS was decreased in the middle and elderly aged group. However, apical endocardial LS was preserved even in the elderly subjects. CONCLUSIONS We proposed normal reference values for layer-specific strain based on both age and gender. This detailed strain analysis provides layer-oriented information with the potential to characterize abnormal findings in various cardiovascular diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Advanced speckle tracking echocardiography allowing a three-myocardial layer-specific analysis of deformation parameters.

AIMS Different layers of myocardium may contribute differently to myocardial deformation. Speckle tracking based on high resolution two-dimensional (2D) echocardiography has been used to define myocardial deformation parameters of whole left ventricular (LV) segments. This study evaluated with a Novell analysis modality allowing layer-specific analysis of deformation if there are differences in...

متن کامل

Comparative Myocardial Deformation in 3 Myocardial Layers in Mice by Speckle Tracking Echocardiography

BACKGROUND Speckle tracking echocardiography (STE) using dedicated high-resolution ultrasound is a relatively new technique that is useful in assessing myocardial deformation in 3 myocardial layers in small animals. However, comparative studies of STE parameters acquired from murine are limited. METHODS A high-resolution rodent ultrasound machine (VSI Vevo 2100) and a clinically validated ult...

متن کامل

Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI). The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed ...

متن کامل

Left Ventricular Systolic Function Changes in Primary Hypertension Patients Detected by the Strain of Different Myocardium Layers

This study investigated left ventricular (LV) systolic dysfunction associated with differential strain among myocardial layers in primary hypertension (PH) patients with or without LV hypertrophy (LVH), and normal patients.In 63 PH and 42 healthy patients, two-dimensional speckle tracking echocardiography was used to measure the peak systolic longitudinal and circumferential strain of the myoca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017