Can Emergency Physicians Perform Common Carotid Doppler Flow Measurements to Assess Volume Responsiveness?
نویسندگان
چکیده
INTRODUCTION Common carotid flow measurements may be clinically useful to determine volume responsiveness. The objective of this study was to assess the ability of emergency physicians (EP) to obtain sonographic images and measurements of the common carotid artery velocity time integral (VTi) for potential use in assessing volume responsiveness in the clinical setting. METHODS In this prospective observational study, we showed a five-minute instructional video demonstrating a technique to obtain common carotid ultrasound images and measure the common carotid VTi to emergency medicine (EM) residents. Participants were then asked to image the common carotid artery and obtain VTi measurements. Expert sonographers observed participants imaging in real time and recorded their performance on nine performance measures. An expert sonographer graded image quality. Participants were timed and answered questions regarding ease of examination and their confidence in obtaining the images. RESULTS A total of 30 EM residents participated in this study and each performed the examination twice. Average time required to complete one examination was 2.9 minutes (95% CI [2.4-3.4 min]). Participants successfully completed all performance measures greater than 75% of the time, with the exception of obtaining measurements during systole, which was completed in 65% of examinations. Median resident overall confidence in accurately performing carotid VTi measurements was 3 (on a scale of 1 [not confident] to 5 [confident]). CONCLUSION EM residents at our institution learned the technique for obtaining common carotid artery Doppler flow measurements after viewing a brief instructional video. When assessed at performing this examination, they completed several performance measures with greater than 75% success. No differences were found between novice and experienced groups.
منابع مشابه
Blood flow in the common carotid artery in term and preterm infants: reproducibility and relation to cardiac output.
AIM To assess the reproducibility of, and determine normative data for, flow volume measurements from the right common carotid artery (CCA) and its relation to left ventricular output (LVO) in stable term and preterm babies using Doppler ultrasound. METHODS Right CCA flow volume was measured using a near focus, high frequency transducer by obtaining intensity weighted mean velocity and right ...
متن کاملHemodynamic analysis of radiation-induced damage in common carotid arteries by using color Doppler ultrasonography
PURPOSE The aim of this study was to assess vascular changes and blood flow abnormalities in the common carotid arteries of patients with head and neck cancers after external radiotherapy, using color Doppler ultrasonography. METHODS We studied 24 patients treated with external radiotherapy for various head and neck cancers. In order to study the acute effects of irradiation on common carotid...
متن کاملInfluence of acetazolamide and CO2 on extracranial flow volume and intracranial blood flow velocity.
BACKGROUND AND PURPOSE The vasomotor response can be tested by means of transcranial Doppler sonography. If a constant vessel diameter is assumed, the flow velocity changes will reflect blood flow volume changes. This hypothesis is difficult to verify. Simultaneous assessment of intracranial flow velocity and extracranial flow volume changes may solve this problem. METHODS We tested vasomotor...
متن کاملNon-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study
INTRODUCTION The assessment of volume responsiveness and the decision to administer a fluid bolus is a common dilemma facing physicians caring for critically ill patients. Static markers of cardiac preload are poor predictors of volume responsiveness, and dynamic markers are often limited by the presence of spontaneous respirations or cardiac arrhythmias. Passive leg raising (PLR) represents an...
متن کاملComparison of magnetic resonance volume flow rates, angiography, and carotid Dopplers. Preliminary results.
BACKGROUND AND PURPOSE We compared the results of conventional angiography, carotid Doppler, and magnetic resonance angiography volume flow rates to determine the clinical utility of volume flow rate assessment of blood flow to the anterior circulation in patients with carotid occlusive disease. METHODS From 11 symptomatic patients, a total of 22 extracranial carotid arteries were studied wit...
متن کامل