ELISPOT Assays in 384-Well Format: Up to 30 Data Points with One Million Cells

نویسندگان

  • Jodi Hanson
  • Srividya Sundararaman
  • Richard Caspell
  • Edith Karacsony
  • Alexey Y. Karulin
  • Paul V. Lehmann
چکیده

Comprehensive immune monitoring requires that frequencies of T cells, producing different cytokines, are measured to establish the magnitude of Th1, Th2, and Th17 components of cell-mediated immunity. Antigen titration provides additional information about the affinity of T cell response. In tumor immunity, it is also advisable to account for determinant spreading by testing multiple epitopes. Efforts for comprehensive immune monitoring would require substantial numbers of PBMC to run the above tests systematically, which in most test cases is limiting. Immune monitoring with ELISPOT assays have been performed, thus far, in a 96-well format. In this study we show that one can increase cell utilization by performing the assay in 384-well plates whose membrane surface area is one third that of 96-well plates. Systematic testing of PBMC for antigen-specific T cell response in the two formats demonstrated that the 384-well assay corresponds to a one-in-three miniaturization of the 96-well assay. The lowest number of cells that can be used in the 384-well format, while allowing for sufficient contact with APC, is 33,000 PBMC/well. Therefore, with one million PBMC typically obtained from 1 mL of blood, a 30 well T cell ELISPOT assay can be performed in a 384-well format.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

خوشه‌بندی داده‌ها بر پایه شناسایی کلید

Clustering has been one of the main building blocks in the fields of machine learning and computer vision. Given a pair-wise distance measure, it is challenging to find a proper way to identify a subset of representative exemplars and its associated cluster structures. Recent trend on big data analysis poses a more demanding requirement on new clustering algorithm to be both scalable and accura...

متن کامل

Detection and removal of spatial bias in multiwell assays

MOTIVATION Multiplex readout assays are now increasingly being performed using microfluidic automation in multiwell format. For instance, the Library of Integrated Network-based Cellular Signatures (LINCS) has produced gene expression measurements for tens of thousands of distinct cell perturbations using a 384-well plate format. This dataset is by far the largest 384-well gene expression measu...

متن کامل

Miniaturization of intracellular calcium functional assays to 1536-well plate format using a fluorometric imaging plate reader.

The measurement of intracellular calcium response transients in living mammalian cells is a popular functional assay for identification of agonists and antagonists to receptors or channels of pharmacological interest. In recent years, advances in fluorescence-based detection techniques and automation technologies have facilitated the adaptation of this assay to 384-well microplate format high-t...

متن کامل

Stepping up ELISpot: Multi-Level Analysis in FluoroSpot Assays

ELISpot is one of the most commonly used immune monitoring assays, which allows the functional assessment of the immune system at the single cell level. With its outstanding sensitivity and ease of performance, the assay has recently advanced from the mere single function cell analysis to multifunctional analysis by implementing detection reagents that are labeled with fluorophores (FluoroSpot)...

متن کامل

Comparative Multi-Donor Study of IFNγ Secretion and Expression by Human PBMCs Using ELISPOT Side-by-Side with ELISA and Flow Cytometry Assays

ELISPOT, ELISA and flow cytometry techniques are often used to study the function of immune system cells. It is tempting to speculate that these assays can be used interchangeably, providing similar information about the cytokine secreting activity of cells: the higher the number of cytokine-positive cells measured by flow cytometry, the higher the number of cytokine-secreting cells expected to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2015