Externalized Guidewires to Facilitate Fenestrated Endograft Deployment in the Aortic Arch
نویسندگان
چکیده
PURPOSE To describe a precannulated fenestrated endograft system utilizing externalized guidewires to facilitate aortic arch endovascular repair and to report its use in 2 patients with challenging anatomy. TECHNIQUE For distal arch repair, a fenestration for the left subclavian artery (LSA) is made onsite in a standard thoracic endograft tailored to the patient anatomy; it is precannulated with a nitinol guidewire (NGw), which is passed from the femoral artery and externalized from the left brachial artery prior to endograft delivery system introduction over a parallel stiff guidewire. Steps are then taken to remove guidewire intertwining, prevent NGw wrapping around the delivery system, and orient the LSA fenestration superiorly when the delivery system moves into the arch. Gentle traction on the ends of the NGw during endograft deployment facilitates proper fenestration alignment. A covered stent is deployed in the LSA fenestration. The technique is illustrated in a patient with congenital coarctation of the aorta and descending aortic aneurysm. For total arch repair, endograft fenestrations are made for all 3 arch branches; the left common carotid artery (LCCA) and LSA fenestrations are each cannulated with NGws, which travel together from the femoral artery, pass through a LSA snare loop, and are exteriorized from the LCCA. After endograft deployment, the innominate artery fenestration is separately cannulated using right brachial access. Placement of a parallel externalized hydrophilic guidewire passing through the LCCA fenestration (but not the LSA snare loop) and removal of the LCCA fenestration NGw allows exteriorization of the LSA fenestration NGw from the left brachial artery by pulling the LSA snare. Covered stents are deployed in all 3 fenestrations. The technique is presented in a patient with type B aortic dissection. CONCLUSION Use of the precannulated fenestrated endograft system described is feasible and has the potential to make aortic arch endovascular repair simpler, more reliable, and safer.
منابع مشابه
Direct videoscopic approach to the thoracic aorta for aortic endograft delivery: evaluation in a human cadaver circulation model.
PURPOSE To examine the feasibility of a direct videoscopic approach to the descending thoracic aorta for branched endograft delivery to the aortic arch and abdominal aorta. METHODS Aneurysms were created in the aortic arch and pararenal aorta of 3 human cadavers, and pulsatile flow was established using a roller pump. Thoracoscopically, 2 double-felted purse-string sutures were placed on the ...
متن کاملA Single-Stage Repair of Arch and Descending Thoracic Aortic Aneurysms Using Jotec E-vita Open Plus Hybrid Stent Graft Combined With Antegrade Deployment of Thoracic Endograft.
We report a unique case of a 63-year-old female with extensive peripheral vascular disease who underwent a single-stage surgical repair of the aortic arch and descending thoracic aortic aneurysm utilizing the Jotec E-vita Open Plus hybrid stent graft system combined with antegrade deployment of a thoracic endograft via a median sternotomy.
متن کاملHybrid arch debranching and endograft repair in a patient with a ruptured thoracic aortic aneurysm.
Recent advances in hybrid techniques of aortic arch debranching allow for the repair of thoracic aortic arch aneurysm without requiring cardiopulmonary bypass or hypothermic circulatory arrest. We describe the repair of a ruptured proximal descending thoracic aortic aneurysm, using off-pump aortic arch debranching and antegrade transaortic deployment of a thoracic endograft in an elderly patient.
متن کاملDirect videoscopic approach to the descending thoracic aorta for aortic arch endograft delivery: evaluation in a porcine model.
PURPOSE To examine the feasibility of a direct videoscopic approach to the descending thoracic aorta for endograft delivery to the aortic arch. METHODS A double purse-string suture was placed on the aorta of 3 pigs via a thoracoscopic approach. Subsequently, the aorta was cannulated in the center of the purse-string. A 22-F delivery catheter was advanced under fluoroscopic control over a guid...
متن کاملApplication of the Bolton Relay Device for Thoracic Endografting In or Near the Aortic Arch.
Endovascular correction of aortic arch pathology remains a challenge, with a variety of techniques proposed over the years to minimize complications and enhance the probability of a successful result. A variety of approaches have been developed in order to deal with the aortic arch pathology and its idiosyncrasies. We review potential interventional techniques for the repair of aortic arch path...
متن کامل