Homograft Aortic Valve Replacement in Aortic Incompetence and Stenosis.
نویسنده
چکیده
The surgery of aortic incompetence and calcific aortic stenosis has made disappointing progress, chiefly because of the need for partial or total valve replacement in many of these patients and the technical problems inherent in designing an artificial valve. In rheumatic aortic incompetence it is now fairly clear that total replacement of the valve is almost always required (McGoon, Mankin, and Kirklin, 1963), and in calcific aortic stenosis the lesion is by no means always adequately relieved by decalcifying the cusps, so that partial or total valve replacement is necessary in a proportion of these cases also. Dissatisfaction with the available plastic aortic valve prostheses led to a review of the experimental and clinical experience with homograft aortic valves. The experimental evidence (Murray, 1956; Lam, Aram, and Munnell, 1952; Brewin, 1956; Beall, Morris, Cooley, and De Bakey, 1961), while a little conflicting, suggests that with the host valve rendered incompetent a homograft valve will function in the dog. Clinical experience from Toronto (Murray, 1956; Kerwin, Lenkei, and Wilson, 1962), where homograft aortic valves have been inserted in the descending thoracic aorta in patients with severe aortic incompetence, shows that these valves will function normally for up to six years. The evidence seemed sufficient to justify attempts to insert homograft valves in a subcoronary position in anticipation that they would function better and for longer periods than plastic prostheses. The technique used for inserting the valve was based on experience gained in approximately 100 open operations on the aortic valve and was first used in August 1962 before receiving the report of a similar procedure performed by Ross (1962) at about the same time. The technique has proved very satisfactory and the valves have all continued to function well. Indeed the experience presented here, including necropsy examination of two valves three and a half and four and a half months after insertion, is most encouraging and suggests that homograft aortic valves are worthy of serious consideration for aortic valve replacement.
منابع مشابه
Aortic homograft valve replacement for postendocarditis aortic incompetence in early childhood. A case report.
A case of postendocarditis aortic incompetence with congenital ventricular septal defect in a 21-month-old child, treated successfully by homograft aortic valve replacement and closure of the ventricular septal defect, is reported. It appears that no similar case has previously been reported in the UK.
متن کاملHomograft valve replacement for aortic valve disease.
Our experience with homograft replacement of the aortic valve now includes 175 patients operated on over a period of almost three years, and we have come to aceept this method as the best surgical treatment for aortic incompetence and for calcific aortic stenosis. As others continue to use a ball valve prosthesis, it is important to analyse the results with the homograft valve, paying particula...
متن کاملRadiology of homograft aortic valves.
A consecutive series of 93 patients had homograft.aortic valve replacement at Green Lane Hospital over a six-month period. Except for 12 assessed at one or two months, the 85 survivors were examined at three months and the clinical degree of aortic incompetence was recorded. Thirty-four of the patients did not proceed to aortography for reasons unrelated to the state of the homograft valve. Fif...
متن کاملPatient outcome and valve performance following a second aortic valve homograft replacement.
BACKGROUND Homograft valves offer many advantages; however, there is concern about their use in second aortic valve replacement because of the complexity of the procedure and the possibility of accelerated degeneration. METHODS AND RESULTS One hundred and forty-four patients underwent a second aortic homograft replacement between 1973 and 1997 (mean follow-up 6.5+/-5 years, range 1 to 20 year...
متن کاملValve-in-valve-in homograft: A case of a repeat transcatheter aortic valve replacement in a patient with an aortic homograft
In recent years, the use of transcatheter aortic valve replacement (TAVR) has extended beyond the treatment of native aortic valve stenosis in patients with high surgical risk. TAVR is increasingly being performed for bioprosthetic aortic valve failure, i.e., the valve-in-valve (VIV) procedure. Establishing the success of a VIV procedure can be challenging in these cases. Furthermore, the limit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 19 شماره
صفحات -
تاریخ انتشار 1964