Modulation of fixation stiffness from flexible to stiff in a rat model of bone healing
نویسندگان
چکیده
Background and purpose - Constant fixator stiffness for the duration of healing may not provide suitable mechanical conditions for all stages of bone repair. We therefore investigated the influence of stiffening fixation on callus stiffness and morphology in a rat diaphyseal osteotomy model to determine whether healing time was shortened and callus stiffness increased through modulation of fixation from flexible to stiff. Material and methods - An external unilateral fixator was applied to the osteotomized femur and stiffened by decreasing the offset of the inner fixator bar at 3, 7, 14, and 21 days after operation. After 5 weeks, the rats were killed and healing was evaluated with mechanical, histological, and microcomputed tomography methods. Constant fixation stiffness control groups with either stiff or flexible fixation were included for comparison. Results - The callus stiffness of the stiff group and all 4 experimental groups was greater than in the flexible group. The callus of the flexible group was larger but contained a higher proportion of unmineralized tissue and cartilage. The stiff and modulated groups (3, 7, 14, and 21 days) all showed bony bridging at 5 weeks, as well as signs of callus remodeling. Stiffening fixation at 7 and 14 days after osteotomy produced the highest degree of callus bridging. Bone mineral density in the fracture gap was highest in animals in which the fixation was stiffened after 14 days. Interpretation - The predicted benefit of a large robust callus formed through early flexible fixation could not be shown, but the benefits of stabilizing a flexible construct to achieve timely healing were demonstrated at all time points.
منابع مشابه
A case for optimising fracture healing through inverse dynamization.
The mechanical conditions in the repair tissues are known to influence the outcome of fracture healing. These mechanical conditions are determined by the stiffness of fixation and limb loading. Experimental studies have shown that there is a range of beneficial fixation stiffness for timely healing and that fixation stiffness that is either too flexible or too stiff impairs callus healing. Howe...
متن کاملImproved healing of large segmental defects in the rat femur by reverse dynamization in the presence of bone morphogenetic protein-2.
BACKGROUND Large segmental defects in bone do not heal well and present clinical challenges. This study investigated modulation of the mechanical environment as a means of improving bone healing in the presence of bone morphogenetic protein (BMP)-2. Although the influence of mechanical forces on the healing of fractures is well established, no previous studies, to our knowledge, have described ...
متن کاملPrediction of the Time Course of Callus Stiffness as a Function of Mechanical Parameters in Experimental Rat Fracture Healing Studies - A Numerical Study
Numerous experimental fracture healing studies are performed on rats, in which different experimental, mechanical parameters are applied, thereby prohibiting direct comparison between each other. Numerical fracture healing simulation models are able to predict courses of fracture healing and offer support for pre-planning animal experiments and for post-hoc comparison between outcomes of differ...
متن کاملSeismic Performance of Torsionally Stiff and Flexible Single Story Buildings Designed Based on Iranian Seismic Code(Standard 2800)
This paper examines differences in performances of a range of torsionally stiff and flexible single story buildings designed with the provisions of Iranian Standard 2800. Seismic nonlinear dynamic time history behavior of eight building models subjected to seven horizontal bi-directional design spectra compatible ground motions are investigated. These models cover a wide range of very torsional...
متن کاملThe effects of flexible fixation on early stage bone fracture healing
The mechanical microenvironment at a fracture site could potentially influence the outcomes of bone fracture healing. It is known that, should the fixation construct be too stiff, or the gap between the fracture ends be too large, bones are less likely to heal. Flexible fixation or so-called “biological fixation” has been shown to encourage the formation of fracture callus, and therefore result...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 88 شماره
صفحات -
تاریخ انتشار 2017