no 1: Technical challenges of fast volumetric rescanning O. Actis, D. Meer, A. Mayor, G. Klimpki, S. Psoroulas, D.C. Weber For pencil beam scanning the most studied method to mitigate the dose delivery uncertainties due to the organ motion is rescanning. Achieving an optimal treatment for a moving target by volumetric rescanning, where the whole tumour volume is scanned multiple times, requires a fast switch between energy layers, a feature which is available at PSI Gantry 2. In volumetric rescanning the spot weight is reduced proportionally to the number of rescans; if the spots weight is below the minimum deliverable weight, it will be skipped, thus impairing the efficacy of rescanning. We supplement a well-known volumetric rescanning algorithm with a smart functionality which allows us to control the delivered spot weight by reducing the number of rescans for spots below a given monitor

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in 4D Treatment Planning for Scanned Particle Beam Therapy — Report of Dedicated Workshops

We report on recent progress in the field of mobile tumor treatment with scanned particle beams, as discussed in the latest editions of the 4D treatment planning workshop. The workshop series started in 2009, with about 20 people from 4 research institutes involved, all actively working on particle therapy delivery and development. The first workshop resulted in a summary of recommendations for...

متن کامل

IMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking

The problem addressed here was to obtain optimal and deliverable dynamic multileaf collimator (MLC) leaf sequences from four-dimensional (4D) geometries for dynamic MLC tracking delivery. The envisaged scenario was where respiratory phase and position information of the target was available during treatment, from which the optimal treatment plan could be further adapted in real time. A tool for...

متن کامل

Reconstruction of 4D-CT from a Single Free-Breathing 3D-CT by Spatial-Temporal Image Registration

In the radiation therapy of lung cancer, a free-breathing 3D-CT image is usually acquired in the treatment day for image-guided patient setup, by registering with the free-breathing 3D-CT image acquired in the planning day. In this way, the optimal dose plan computed in the planning day can be transferred onto the treatment day for cancer radiotherapy. However, patient setup based on the simple...

متن کامل

Analysis of 3d and 4d Proton Treatment Planning for Hepatic Tumors

The purpose of this study is to assess the difference between 4D liver dose calculations versus standard 3D treatment planning and to investigate the dosimetric gain of gating on radiation dose to normal tissue. 4DCT scans are collected for 25 patients with hepatic tumors treated by proton radiotherapy. The 4D treatment planning process explicitly takes into account respiratory motion of abdomi...

متن کامل

Status of 4D Treatment Planning Implementations for TRiP98

TRiP98 is a treatment planning program for radiotherapy with scanned ion beams. It was developed at GSI and has been successfully used in clinical routine from 1997-2008 for over 400 patients, predominantly with head and neck tumors [1,2]. The treatment of tumors within moving organs, such as lung tumors, with scanned ion beams involves additional complexity of the beam delivery and the treatme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016