Accuracy of Linear Measurements Using Cone Beam Computed Tomography in Comparison with Clinical Measurements
نویسندگان
چکیده
OBJECTIVES This study sought to evaluate the accuracy and errors of linear measurements of mesiodistal dimensions of Kennedy Class III edentulous space using cone beam computed tomography (CBCT) in comparison with clinical measurements. MATERIALS AND METHODS Nineteen Kennedy Class III dental arches were evaluated. An impression was made of each dental arch and poured with dental stone. The distance was measured on dental cast using a digital Vernier caliper with an accuracy of 0.1mm and on CBCT scans. Finally, the linear mesiodistal measurements were compared and the accuracy of CBCT technique was evaluated by calculating absolute value of errors, intra-class correlation coefficient and simple linear regression model. RESULTS In comparison with the cast method, estimation of size on CBCT scans had an error of -8.46% (underestimation) to 5.21% (overestimation). In 26.5% of the cases, an accepted error of ±1% was found. The absolute value of errors was found to be in the range of 0.21-8.46mm with an average value of 2.86 ±2.30mm. CONCLUSIONS Although the measurements revealed statistically significant differences, this does not indicate a lower accuracy for the CBCT technique. In fact, CBCT can provide some information as a paraclinical tool and the clinician can combine these data with clinical data and achieve greater accuracy. Undoubtedly, calibration of data collected by clinical and paraclinical techniques and the clinician's expertise in use of CBCT software programs can increase the accuracy of implant placement.
منابع مشابه
Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...
متن کاملThe Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible
Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملEvaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study
Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...
متن کاملEvaluation the Accuracy of Lineartomography in Determining the Quantity of Maxillary Bone
Background & Aims: The accuracy of dental implants has increased in recent years. An accurate radiography from the region is needed for precise treatment planning in implants and for determining prognosis of treatment. Because this technique can demonstrate the buccolingual aspect, and due to its lower radiation dose, lower cost, and availability, in comparison with computed tomography, lineart...
متن کامل