A compact model for early electromigration failures of copper dual-damascene interconnects
نویسندگان
چکیده
A compact model for early electromigration failures in copper dual-damascene interconnects is proposed. The model is based on the combination of a complete void nucleation model together with a simple mechanism of slit void growth under the via. It is demonstrated that the early electromigration lifetime is well described by a simple analytical expression, from where a statistical distribution can be conveniently obtained. Furthermore, it is shown that the simulation results provide a reasonable estimation for the lifetimes.
منابع مشابه
Investigation of the Fundamental Reliability Unit for Cu Dual-damascene Metallization
An investigation has been carried out to determine the fundamental reliability unit of copper dual-damascene metallization. Electromigration experiments have been carried out on straight via-to-via interconnects in the lower metal (M1) and the upper metal (M2), and in a simple interconnect tree structure consisting of straight via-to-via line with an extra via in the middle of the line (a “dott...
متن کاملModeling Electromigration Lifetimes of Copper Interconnects
A model for early failure due to electromigration in copper dualdamascene interconnects is proposed. The model is based on analytical expressions obtained from solutions of electromigration stress build-up assuming slit void growth under the interconnect vias. It is demonstrated that the model satisfactorily describes the complex physics of void nucleation and growth of the electromigration dam...
متن کاملStress-Induced Anisotropy of Electromigration in Copper Interconnects
Abstract. Modern interconnect structures are exposed to high mechanical stresses during their operation. These stresses have their sources in interconnect process technology and electromigration. The mechanical properties of passivating films and the choice of process technology influence electromigration reliability. In this paper we analyze the interplay between electromigration and mechanica...
متن کاملP 17 Microstructure and Stress Aspects of Electromigration Modeling
The electromigration behaviour of copper interconnects realized in damascene architecture indicates macroscopic and microscopic electromigration divergence sites. Macroscopic divergence sites exist at the cathode end of via bottoms where the barrier layer can be a blocking boundary for the electromigration flux. As microscopic divergence can be considered triple point sites of the grain boundar...
متن کاملEffects of length scaling on electromigration in dual-damascene copper interconnects
The electromigration short-length effect in dual-damascene Cu interconnects has been investigated through experiments on lines of various lengths (L), being stressed at a variety of current densities (j), and using a technologically realistic three-level structure. This investigation represents a complete study of the short-length effect after a well-developed dual-damascene Cu process. Lifetim...