An evaluation of a spectrophotometric scanning technique for measurement of plasma hemoglobin.
نویسندگان
چکیده
The measurement of plasma hemoglobin is utilized in the evaluation of various hemolytic disorders. The purpose of this report is to illustrate the advantages of a direct spectrophotometric scanning technique for determination of of plasma hemoglobin. This method does not require the use of carcinogenic reagents. The scanning method demonstrates linearity, precision, and sensitivity suitable for clinical use and is not affected by the presence of bilirubin.
منابع مشابه
Evaluation of Nitrogen Diffusion in Plasma Nitrided Iron by Various
Diffusion of nitrogen in plasma nitrided iron and structural evolution during the nitriding process were evaluated by several characterization techniques including optical microscopy (OM), microhardness depth profiling (HDP), scanning electron microscopy (SEM), x-ray diffraction (XRD), glow discharge optical emission spectroscopy (GDOES), and secondary ion mass spectroscopy (SIMS). Plasma ni...
متن کاملO-13: Evaluation of Leptin Concentration in Seminal Plasma and Its Correlation with Reactive Oxygen Species, Lipid Peroxidation and Pronuclear Formation in Candidates for ICSI Treatment
Background Leptin, as a key hormone in energy homeostasis, plays an important role in reproduction and male fertility. However, its negative or positive effect on sperm quality and assisted reproduction technique is still controversial. The aim of this study was the comparison of seminal leptin concentration in selected couples with male and female factor for intracytoplasmic microinjection (IC...
متن کاملEvaluating the Reliability of an Accurate Performance in Tray Columns Using Gamma Ray Scanning Technique
The nondestructive techniques are applied to identify important data from the internal process of distillation towers, process towers, pressure vessels and etc. In recent, the gamma-ray scanning techniques as diagnostic tools for scanning of tray columns, packed columns, storage tanks, level measurement and density measurement of containing materials has been used widely. This paper has tried t...
متن کاملاستفاده از گرماسنجی روبشی تفاضلی در تشخیص مراحل اولیه سرطانها: گزارش کوتاه
Background: Cancer is the most common cause of death in the world, and it incidence has been increasing for many years in economically developed countries. Early detection of cancers greatly increases the chances for successful treatment. So finding cancers before they start to cause symptoms is a most effective treatment. Recent studies have proposed that blood plasma contains a rich source of...
متن کاملPreparation and evaluation of latex agglutination technique for diagnosis and seroepidemiological studies of visceral leishmaniasis
in this study which has been carried out from 1996 until 1997 soluble latex agglutination antigen was prepared from L, donovani,sudan(s-1) by culturing in special media,harvesting,and later solubilizing by freezing and thawing.the antigen were futher prepared by high speed centrifugation.after measurement of the protein (lowry method) concentration of the antigen was set at 2.2 mg/ml,the antige...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 11 2 شماره
صفحات -
تاریخ انتشار 1981