Pii: S0301-5629(01)00442-2
نویسندگان
چکیده
Elastic properties of tendon were assessed by two different approaches. Six fresh bovine Achilles tendon specimens were used. The first approach directly measured Young’s modulus along the transverse direction (Eperpendicular) and the longitudinal direction (Eparallel), using a cyclic compression–relaxation method. Young’s moduli were derived based on the measured strain and stress values. The ratio of Eparallel: Eperpendicular at smaller strains was around 4 and decreased to 0.6 1.1 at larger strains. The second approach assumed that tendons are transversely isotropic. Three observable second-order elastic stiffness constants (c11, c13 and c33) were obtained by sound speed measurements along various propagation directions. The measured elastic stiffness constants were also correlated with results from the first approach. It was shown that the transverse isotropy assumption was valid at small strains. However, a significant discrepancy existed between the two approaches. The discrepancy was primarily due to viscoelasticity associated with the first approach. (E-mail: [email protected]) © 2001 World Federation for Ultrasound in Medicine & Biology.
منابع مشابه
Pii: S0301-5629(01)00472-0
The nonstationary variation in the noise performance of the cross-correlation-based strain estimator due to frequency-dependent attenuation and lateral and elevational signal decorrelation have been addressed theoretically in recent papers using the strain-filter approach. In this paper, we present the experimental verification and corroboration of the nonstationary effects on the strain estima...
متن کاملPii: S0301-5629(01)00478-1
In this paper we propose a novel feature-based contrast enhancement approach to enhance the quality of noisy ultrasound (US) images. Our approach uses a phase-based feature detection algorithm, followed by sparse surface interpolation and subsequent nonlinear postprocessing. We first exploited the intensity-invariant property of phase-based acoustic feature detection to select a set of relevant...
متن کاملPii: S0301-5629(01)00411-2
This study consisted of two parts. In the first part, the contrast-transfer efficiency (CTE) in elastography was extended to account for continuous changes of modulus distribution. It was shown that, for a finite size background, the strain contrast approaches the modulus contrast in the case of Gaussian distributions. Thus, an increase in the CTE was obtained. For a fixed background size, it w...
متن کاملPii: S0301-5629(01)00421-5
Using catheter-mounted 2-D array transducers, we have obtained real-time 3-D intracardiac ultrasound (US) images. We have constructed several transducers with 64 channels inside a 12 French catheter lumen operating at 5 MHz. The transducer configuration may be side-scanning or beveled, with respect to the long axis of the catheter lumen. We have also included six electrodes to aquire simultaneo...
متن کاملPii: S0301-5629(01)00486-0
Difficulties in location of transcranial ultrasound (US) windows and blood flow in cerebral vessels, and unambiguous detection of microemboli, have limited expansion of transcranial Doppler US. We developed a new transcranial Doppler modality, power M-mode Doppler (PMD), for addressing these issues. A 2-MHz digital Doppler (Spencer Technologies TCD100M) having 33 sample gates placed with 2-mm s...
متن کامل