Graded Maximal Exercise Testing to Assess Mouse Cardio-Metabolic Phenotypes

نویسندگان

  • Jennifer M. Petrosino
  • Valerie J. Heiss
  • Santosh K. Maurya
  • Anuradha Kalyanasundaram
  • Muthu Periasamy
  • Richard A. LaFountain
  • Jacob M. Wilson
  • Orlando P. Simonetti
  • Ouliana Ziouzenkova
  • Yann Herault
چکیده

Functional assessments of cardiovascular fitness (CVF) are needed to establish animal models of dysfunction, test the effects of novel therapeutics, and establish the cardio-metabolic phenotype of mice. In humans, the graded maximal exercise test (GXT) is a standardized diagnostic for assessing CVF and mortality risk. These tests, which consist of concurrent staged increases in running speed and inclination, provide diagnostic cardio-metabolic parameters, such as, VO2max, anaerobic threshold, and metabolic crossover. Unlike the human-GXT, published mouse treadmill tests have set, not staged, increases in inclination as speed progress until exhaustion (PXT). Additionally, they often lack multiple cardio-metabolic parameters. Here, we developed a mouse-GXT with the intent of improving mouse-exercise testing sensitivity and developing translatable parameters to assess CVF in healthy and dysfunctional mice. The mouse-GXT, like the human-GXT, incorporated staged increases in inclination, speed, and intensity; and, was designed by considering imitations of the PXT and differences between human and mouse physiology. The mouse-GXT and PXTs were both tested in healthy mice (C57BL/6J, FVBN/J) to determine their ability to identify cardio-metabolic parameters (anaerobic threshold, VO2max, metabolic crossover) observed in human-GXTs. Next, theses assays were tested on established diet-induced (obese-C57BL/6J) and genetic (cardiac isoform Casq2-/-) models of cardiovascular dysfunction. Results showed that both tests reported VO2max and provided reproducible data about performance. Only the mouse-GXT reproducibly identified anaerobic threshold, metabolic crossover, and detected impaired CVF in dysfunctional models. Our findings demonstrated that the mouse-GXT is a sensitive, non-invasive, and cost-effective method for assessing CVF in mice. This new test can be used as a functional assessment to determine the cardio-metabolic phenotype of various animal models or the effects of novel therapeutics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional Speed Reserve as a Proxy for the Anaerobic Speed Reserve Using the Critical Speed Concept

Background: Although maximal sprint speed (MSS) and the anaerobic speed reserve (ASR) provides valuable information about the speed profile of athletes, these parameters fall short of providing important information about sub-maximal metabolic thresholds. The only field test that can offer an estimate of a sub-maximal metabolic threshold is the 3-minute all-out test for running (3MT) which deli...

متن کامل

Poor glycaemic control is associated with reduced exercise performance and oxygen economy during cardio-pulmonary exercise testing in people with type 1 diabetes

Background To explore the impact of glycaemic control (HbA1c) on functional capacity during cardio-pulmonary exercise testing in people with type 1 diabetes. Methods Sixty-four individuals with type 1 diabetes (age: 34 ± 8 years; 13 females, HbA1c: 7.8 ± 1% (62 ± 13 mmol/mol), duration of diabetes: 17 ± 9 years) performed a cardio-pulmonary cycle ergometer exercise test until volitional exhau...

متن کامل

Sudomotor Function as a Tool for Cardiorespiratory Fitness Level Evaluation: Comparison with Maximal Exercise Capacity

Physical inactivity is a modifiable risk factor for cardiovascular (CV) and metabolic disorders. VO2max is the best method to assess cardio-respiratory fitness level but it is poorly adopted in clinical practice. Sudomotor dysfunction may develop early in metabolic diseases. This study aimed at comparing established CV risk evaluation techniques with SUDOSCAN; a quick and non-invasive method to...

متن کامل

Symptom-limited graded treadmill exercise testing in young adults in the CARDIA study.

Symptom-limited, graded exercise treadmill testing was performed by 4,968 white and black adults, ages 18-30 yr, during the baseline examination for the CARDIA study. The mean estimated maximal exercise capacity by race/gender, expressed as metabolic units (METS), was: white men 13.8, black men 13.0, white women 11.1, and black women 9.4. Exercise test duration was higher in nonsmokers, positiv...

متن کامل

Validation of the CardioCoachCO2 for submaximal and maximal metabolic exercise testing.

This study examined the validity of the CardioCoachCO2 metabolic system to measure oxygen capacity by comparison to a previously validated device. Fourteen subjects (8 men and 6 women; 25.9 +/- 6.6 years of age) completed 2 maximal graded exercise tests on a cycle ergometer. Subjects were randomly tested on the CardioCoachCO2 and Medical Graphics CardiO2/CP (MedGraphics) system on 2 separate vi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016