Harmonisation of factor VIII:C assay results: study within the framework of the Dutch project 'Calibration 2000'.

نویسندگان

  • Anton M H P van den Besselaar
  • Fred J L M Haas
  • Aldy W H M Kuypers
چکیده

In a Dutch project for harmonisation of factor VIII coagulant activity (FVIII:C) assays, the commutability of potential calibrators for FVIII:C was assessed by means of a 'twin-study design', which is in essence a multi-centre, split-patient sample, between-field-methods protocol. Commutability was defined as the degree to which a material yielded the same numerical relationships between results of measurements by a given set of measurement procedures as those between the expectations of the relationships for the same procedures applied to those types of material for which the procedures were intended. The study consisted of the simultaneous analysis of fresh frozen patient plasmas and three potential calibrators for FVIII:C by 16 Dutch laboratories forming eight couples. The state-of-the-art intra-laboratory standard deviation was used to assess the commutability of the potential calibrators. One potential calibrator was used to harmonise FVIII:C assay results in a Dutch field study. The inter-laboratory coefficient of variation of two test samples could be reduced significantly, but no significant effect was observed with three other test samples. We recommend that at least three different sample dilutions be used in each FVIII:C assay, in agreement with previous recommendations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Harmonization of fibrinogen assay results: study within the framework of the Dutch project 'Calibration 2000'.

In a Dutch project for harmonization of fibrinogen assays, the commutability of potential calibrators for fibrinogen was assessed by means of a twin-study design, which is, in essence, a multicentre, split-patient sample, between-field-methods protocol. The study consisted of simultaneous analysis of fresh-frozen patient plasmas and three potential calibrators for fibrinogen by 48 Dutch laborat...

متن کامل

Harmonization and external quality assessment of antithrombin activity assays.

UNLABELLED In the framework of a Dutch project named "Calibration 2000" harmonization of antithrombin activity assays was studied. The commutability of potential calibrators for antithrombin was assessed by means of a twin-study design, which is a multicentre, split-patient sample, between-field-methods protocol. The twin-study consisted of simultaneous analysis of fresh-frozen patient plasmas ...

متن کامل

Stabilization of thrombin-activated porcine factor VIII:C by factor IXa phospholipid.

The activation of porcine factor X by an enzymatic complex consisting of activated factor IX (factor IXa), thrombin-activated factor VIII:C (factor VIII:Ca), phospholipid vesicles, and calcium was studied in the presence of an irreversible inhibitor of factor Xa, 5-dimethylamino-naphthalene-1-sulfonyl-glutamyl-glycyl-arginyl- chloro met hyl ketone ( DEGR -CK). The formation of factor Xa was mea...

متن کامل

پیشنهاد چارچوبی مفهومی جهت معماری دانش سازمان‌های کلان مقیاس

The main concern for most organizations in this age, which has been called the age of knowledge-based economy, is their success and superiority in competitive markets. Reviewing the parameters that might have been effective on the success of operationalizing a knowledge management project leads us to a potential factor as knowledge architecture. With regard to the significant effect of knowledg...

متن کامل

Using SWAT and SWAT-CUP for hydrological simulation and uncertainty analysis in arid and semi-arid watersheds (Case study: Zoshk Watershed, Shandiz, Iran)

The aims of this project was to assess the capability of SWAT model and SWAT-CUP software in hydrological simulation and to evaluate the uncertainty of SWAT model in estimating runoff in arid and semi-arid watersheds. Model calibration and uncertainty analysis were performed using the Sequential Uncertainty Fitting (SUFI2) algorithm. In the stage of calibration and validation of water flow, per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of haematology

دوره 132 1  شماره 

صفحات  -

تاریخ انتشار 2006