Evaluation of the soft tissue treatment simulation module of a computerized cephalometric program
نویسندگان
چکیده
OBJECTIVE The purpose of this study is to compare the accuracy of the treatment simulation module of Quick Ceph Studio (QCS) program to the actual treatment results in Class II Division 1 patients. DESIGN Retrospective study. MATERIALS AND METHODS Twenty-six skeletal Class II patients treated with functional appliances were included. T0 and T1 lateral cephalograms were digitized using QCS. Before applying treatment simulation to the digitized cephalograms, the actual T0-T1 difference was calculated for the SNA, SNB, ANB angles, maxillary incisor inclination, and protrusion and mandibular incisor inclination and protrusion values. Next, using the treatment simulation module, the aforementioned values for the T0 cephalograms were manually entered to match the actual T1 values taking into account the T0-T1 differences. Paired sample t-test were applied to determine the difference between actual and treatment simulation measurements. RESULTS No significant differences were found for the anteroposterior location of the landmarks. Upper lip, soft tissue A point, soft tissue pogonion, and soft tissue B point measurements showed statistically significant difference between actual and treatment simulation in the vertical plane. CONCLUSION Quick Ceph program was reliable in terms of reflecting the sagittal changes that would probably occur with treatment and growth. However, vertical positions of the upper lip, soft tissue pogonion, soft tissue A point, and soft tissue B point were statistically different from actual results.
منابع مشابه
Cephalometric evaluation of patients with Class III malocclusion after face mask therapy in mixed dentition period
Cephalometric evaluation of patients with Class III malocclusion after face mask therapy in mixed dentition period Dr. MS. A Akhoundi * - Dr. A. Khorshidian ** * Associate Professor of Orthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University of Medical Sciences. ** Dentist. Abstract Background and Aim: Among different treatment options for patients with Class III m...
متن کاملمقایسه اندازهگیریهای به دست آمده از آنالیز مک نامارا با معادلهای پیشنهادی روی بافت نرم
Background and Aims: Cephalometric measurements cannot be performed for screening purposes, therefore orthodontists usually have to use either photographic or anthropometric measurements in such occasions. Finding a valid and reliable alternative could be of great value. The purpose of this study was to evaluate the correlation between McNamara's cephalometric unit difference and a proposed sof...
متن کاملValidity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy
OBJECTIVES The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical ortho...
متن کاملتغییرات نیمرخ بافت نرم صورت متعاقب رترکشن دندان های انسیزور در گروه سنی 15 تا 24 سال
The purpose of this study was to investigate the soft tissue profile changes of the lower face following premolars extraction and incisor retraction. In order to do that, pre-and post treatment lateral cephalometric radiographs of 40 female orthodontic patients, with cl. II div. I malocclusion (22 patients) and bialveolar protrusion (11 patients) were analyzed. At beginning of orthodontic treat...
متن کاملReliability of four different computerized cephalometric analysis programs: a methodological error.
The aim of this investigation was to compare the traditional method of manual cephalometric tracing with four different computerized tracing programs, where the lateral cephalograms were scanned at 300 dpi and digitized onscreen. Thirty randomly selected cephalometric radiographs were used in this study. Four programs Dolphin Imaging, Vistadent, Nemoceph, and Quick Ceph were evaluated. Three de...
متن کامل