13CO2 breath tests in non-invasive hepatological diagnosis

نویسندگان

  • Joanna Musialik
  • Krzysztof Jonderko
  • Anna Kasicka-Jonderko
  • Magdalena Buschhaus
چکیده

In liver diagnostics, a simple, non-invasive test with high sensitivity and specificity is permanently being sought in order to assess the degree of liver damage. In addition to liver biopsy, algorithms using blood parameters or elastometry are used in clinical practice. However, these methods do not provide information about the true liver reserve, so the liver breath test seem to be a promising diagnostic tool. The basis of this test depends on the ability of particular hepatocyte enzyme systems to metabolise a tested substance labelled with a stable carbon isotope. The kinetics of (13)CO2 elimination with expiratory air then permits quantitative assessment of the functional liver reserve and the degree of organ damage. In this paper the most commonly used tests, grouped according to the main metabolic pathways, are described. The usefulness of liver breath tests in specific clinical situations, both as a diagnostic and prognostic tool, is presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive assessment of intraluminal lipolysis using a 13CO2 breath test.

Techniques available for the study of lipase activity in the gut are unsatisfactory. Breath tests measuring labelled carbon dioxide (13CO2) may provide a useful means for this assessment. Six subjects with cystic fibrosis and pancreatic insufficiency and 10 controls received a test meal containing [13C] trioctanoin, and breath 13CO2 was measured using a dual inlet, dual detector isotope ratio m...

متن کامل

C-egg white breath test: a non-invasive test of pancreatic trypsin activity in the small intestine

Background—The recent availability of egg white protein highly enriched with C has allowed breath test technology to be adapted for the study of protein digestion and absorption. Pancreatic trypsin is considered to be the key enzyme in the proteolytic cascade. Aim—To evaluate trypsin activity in the small intestine of healthy volunteers and patients with pancreatic disease by a recently develop...

متن کامل

Exocrine pancreatic insufficiency: accuracy and clinical value of the uniformly labelled 13C-Hiolein breath test.

BACKGROUND AND AIMS The 13C-Hiolein breath test (98% [U-13C] labelled long chain triglyceride mixture (highly labelled triolein) was evaluated as a non-invasive, non-radioactive test for exocrine pancreatic insufficiency. Accuracy and clinical validity were examined with reference to both the secretin pancreozymin test and faecal fat analysis. METHODS A secretin pancreozymin test and faecal f...

متن کامل

C carbohydrate breath tests

In paediatric practice proper digestion of carbohydrates is of major importance for adequate growth and development and for prevention of intestinal complaints. Several carbohydrates can be considered in this respect: (a) lactose: the main carbohydrate in the nutrition of early life and also in later life for many white people; (b) starch: the main energy supplier in our food; (c) fructose: a c...

متن کامل

A valid, accurate, oYce based non-radioactive test for gastric emptying of solids

Background—Current breath tests for measurement of gastric emptying of solids are expensive, possibly inaccurate, and require cumbersome calculations. Aims—We wished to validate a simplified solid gastric emptying test using a [C]Spirulina platensis breath test for accurate results relative to scintigraphy. Subjects—Thirty healthy volunteers. Methods—We measured gastric emptying of egg containi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015