Estimation of an image derived input function with MR-defined carotid arteries in FDG-PET human studies using a novel partial volume correction method.

نویسندگان

  • Hasan Sari
  • Kjell Erlandsson
  • Ian Law
  • Henrik Bw Larsson
  • Sebastien Ourselin
  • Simon Arridge
  • David Atkinson
  • Brian F Hutton
چکیده

Kinetic analysis of 18F-fluorodeoxyglucose positron emission tomography data requires an accurate knowledge the arterial input function. The gold standard method to measure the arterial input function requires collection of arterial blood samples and is an invasive method. Measuring an image derived input function is a non-invasive alternative but is challenging due to partial volume effects caused by the limited spatial resolution of the positron emission tomography scanners. In this work, a practical image derived input function extraction method is presented, which only requires segmentation of the carotid arteries from MR images. The simulation study results showed that at least 92% of the true intensity could be recovered after the partial volume correction. Results from 19 subjects showed that the mean cerebral metabolic rate of glucose calculated using arterial samples and partial volume corrected image derived input function were 26.9 and 25.4 mg/min/100 g, respectively, for the grey matter and 7.2 and 6.7 mg/min/100 g for the white matter. No significant difference in the estimated cerebral metabolic rate of glucose values was observed between arterial samples and corrected image derived input function (p > 0.12 for grey matter and white matter). Hence, the presented image derived input function extraction method can be a practical alternative to noninvasively analyze dynamic 18F-fluorodeoxyglucose data without the need for blood sampling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of 3 methods of automated internal carotid segmentation in human brain PET studies: application to the estimation of arterial input function.

UNLABELLED Quantitative brain (18)F-FDG PET studies often require the plasma time-activity curve (input function) for estimation of the cerebral metabolic rate of glucose (CMRglc). The gold standard for input function measurement is arterial blood sampling, which is invasive and time-consuming. Alternatively, input function can be estimated from dynamic images. This estimation often implies the...

متن کامل

Improved Imaged-derived Input Function for Study of Human Brain FDG-PET

A reliable, semi-automated method for estimation of a minimally-invasive image-derived input function is validated for human [F]-fluoro deoxyglucose (FDG) positron emission tomography (PET) studies. Two time windows can be recognized in the time activity curve measured from a carotid artery region of interest (CA-ROI). During the first short window of very rapid change, the dominant contaminati...

متن کامل

Wavelet-based partial volume effect correction for simultaneous MR/PET of the carotid arteries

Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, NY, NY, USA Simultaneous MR/PET scanners allow for the exploration and development of novel PVE correction techniques without the challenges of coregistration of MR and PET. The development of a wavelet-based PVE correction method, to improve PET quantification, has proven successful in brain PET. We report ...

متن کامل

Cerebral blood flow with [15O]water PET studies using an image-derived input function and MR-defined carotid centerlines.

Full quantitative analysis of brain PET data requires knowledge of the arterial input function into the brain. Such data are normally acquired by arterial sampling with corrections for delay and dispersion to account for the distant sampling site. Several attempts have been made to extract an image-derived input function (IDIF) directly from the internal carotid arteries that supply the brain a...

متن کامل

Characterization of the image-derived carotid artery input function using independent component analysis

We previously developed a noninvasive technique for the quantification of fluorodeoxyglucose (FDG) positron emission tomography (PET) images using an image-derived input function obtained from a manually drawn carotid artery region. Here, we investigate the use of independent component analysis (ICA) for more objective identification of the carotid artery and surrounding tissue regions. Using F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 2017