Exit of catheter lock solutions from double lumen acute haemodialysis catheters--an in vitro study.
نویسندگان
چکیده
BACKGROUND Double lumen dialysis catheters are routinely heparin or citrate 'locked' to maintain patency. Heparin lock-related bleeding episodes and antibiotic lock-related toxicity have been reported. The aim of this study is to quantify the amount of leak during 'lock' procedures and to compare leakage for different double lumen dialysis catheters. METHODS In an experimental, in vitro study at a University research laboratory, five different double lumen dialysis catheters were tested using three different lock volumes. RESULTS Using the catheter flush volume, leak ratios for Flexxicon II 15 cm and 20 cm catheters were greater than that seen in the Arrow 16 cm catheter (P < 0.05). Using 20% less than the catheter flush volume, the Flexxicon II 20 cm catheter had greater leak than the Duo-flow 15 and 20 cm catheters and Arrow 16 cm catheter (P < 0.05). The Flexxicon II 15 cm catheter had greater leak than the Duo-flow 15 cm and Duo-flow 20 cm catheters with 20% less locking volume (P < 0.05). Using 20% greater than the catheter flush volume, the Duo-flow 20 cm catheter had significantly less leak ratio than the Flexxicon II 20 cm catheter (P < 0.05). There were no other significant differences in leak ratios between the catheters. CONCLUSION All double lumen dialysis catheters we tested have a substantial amount of leak even when the catheter 'lock' volumes were used, and leak ratio increases significantly with 20% overfill. There is a leak even when using 20% less 'lock' volume. The amount of leak can be clinically important and may explain the reports of bleeding episodes after heparin lock and antibiotic toxicity after antibiotic and anticoagulant combination lock. Some devices have lower leak ratios than others, likely related to catheter design.
منابع مشابه
Successful prevention of tunneled, central catheter infection by antibiotic lock therapy using cefotaxime
BACKGROUND Chronic hemodialysis patients frequently require vascular access through central venous catheters (CVCs). The most significant complication of these catheters is infection. This risk can be lowered by the use of an antibiotic-Heparin lock. This study focuses on hemodialysis patients using Tunneled-cuffed catheters (TCC), to assess the rate of catheter-related infections (CRI) in cath...
متن کاملSurvey of permanent central venous catheters for haemodialysis in the UK.
BACKGROUND Venous catheter haemodialysis may be necessary in some patients without arterio venous fistulae on dialysis for end-stage renal failure. We conducted a survey to compare management of these catheters in different units in the UK. METHODS Postal questionnaires were sent to nurses in charge of 81 renal units in the UK for a twelve month study period in 1994 to find out the type of ca...
متن کاملThe Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کاملTrisodium citrate induced protein precipitation in haemodialysis catheters might cause pulmonary embolism.
BACKGROUND The locking anticoagulant plays a decisive role in the patency of central venous catheters (CVCs) used for haemodialysis. During injection, the hydraulic effects inevitably cause lock solution to spill into the systemic circulation. Density differences between whole blood (WB) and the lock solution cause further gravity-induced seepage of lock solution. This is followed by an influx ...
متن کاملInsufficient penetration of systemic vancomycin into the PermCath lumen.
BACKGROUND Catheter infection is a major cause of morbidity and catheter loss in chronic haemodialysis patients. There has been a large discrepancy in the catheter salvage rate, after an episode of documented bacteraemia, whether the patients receive systemic antibiotic alone or systemic antibiotics concomitant with 'antibiotic-lock technique' (20-30% vs 100%, respectively). To test the hypothe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 22 12 شماره
صفحات -
تاریخ انتشار 2007