Perimetric sensitivity and response variability in glaucoma with single-stimulus automated perimetry and multiple-stimulus perimetry with verbal feedback.

نویسندگان

  • Marco A Miranda
  • David B Henson
چکیده

PURPOSE To measure perimetric sensitivity and response variability of glaucomatous patients with single-stimulus automated perimetry (SSAP) and multiple-stimulus perimetry (MSP) with verbal feedback. METHODS Frequency-of-seeing (FOS) data were collected from the same four visual field locations (normal and reduced sensitivity) in one eye of 10 glaucoma patients, using SSAP and MSP. The SSAP technique was similar to that used in routine clinical perimetry while the MSP technique required the patient to verbally report the positions of the seen stimuli (0-4, with no more than 1 in each quadrant) after each presentation. At each test location, stimuli (0.5 degrees , 200 ms) were repeatedly presented at five or more intensities around the estimated threshold. FOS curves (logistic) were determined using a maximum likelihood method and the threshold sensitivity (50% seen) and response variability (20-80% seen range) were compared between the two perimetric techniques. RESULTS There was an increase in sensitivity (mean = 1.9 dB, P < 0.01, Wilcoxon) and reduction in variability (mean range reduced from 3.7 to 2.5 dB, P < 0.01, Wilcoxon) with MSP. The increase in sensitivity with MSP varied between patients (P < 0.001, one-way anova) with the mean MSP-SSAP sensitivity per eye ranging from 0.1 to 4.8 dB. CONCLUSION Patients have a higher sensitivity and less variability in their visual field when tested with MSP with verbal feedback than with SSAP. These differences vary between patients and a likely explanation is the better maintenance of attention with MSP and verbal feedback. This finding demonstrates how the variability found in routine clinical perimetry can be reduced through changes to the way in which the stimuli are presented and the way in which the patient responds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Choice of Stimulus Range and Size Can Reduce Test-Retest Variability in Glaucomatous Visual Field Defects.

PURPOSE To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. METHODS Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ce...

متن کامل

Repeatability of automated perimetry: a comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry.

PURPOSE Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP ...

متن کامل

Glaucomatous visual field damage. Luminance and color-contrast sensitivities.

Using a modified Humphrey perimeter, we evaluated 16 eyes with primary open-angle glaucoma and visual field loss (defects 0.5-3.0 log units in depth), and 14 normal eyes. Each eye was tested twice in random order with conventional luminance-increment static perimetry and with the perimeter modified to produce a high-luminance yellow adapting background and a blue test stimulus. The background w...

متن کامل

[Sensitivity of size I stimulus in achromatic automated perimetry for detection of glaucomatous visual field defects: a comparative analysis with short wavelength automated perimetry and standard automated perimetry (SITA)].

PURPOSE To compare sensitivity and specificity of achromatic perimetry with size I stimulus (WW-I) with standard automated perimetry (SITA strategy) and blue on yellow perimetry (SWAP) for early diagnosis of glaucoma. METHODS Seventy-three eyes of 73 suspects, glaucomatous and normal subjects underwent automated perimetry with SITA 24-2, WW-I and SWAP. After application of specific criteria o...

متن کامل

Automated Perimetry Under the Microscope: A Re-Examination of Fundamental Assumptions.

Automated perimetry, a vision test that is likely performed thousands of times a day within the Unites States alone, has been conducted largely unchanged for several decades. It is also true that many of the fundamental parameters of this form of testing were adopted wholesale from manual kinetic perimetry. Research is now emerging, which suggests that many aspects of automated perimetry, from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta ophthalmologica

دوره 86 2  شماره 

صفحات  -

تاریخ انتشار 2008