The influence of femoral internal and external rotation on cartilage stresses within the patellofemoral joint.

نویسندگان

  • Thor F Besier
  • Garry E Gold
  • Scott L Delp
  • Michael Fredericson
  • Gary S Beaupré
چکیده

Internal and external rotation of the femur plays an important role in defining the orientation of the patellofemoral joint, influencing contact areas, pressures, and cartilage stress distributions. The purpose of this study was to determine the influence of femoral internal and external rotation on stresses in the patellofemoral cartilage. We constructed finite element models of the patellofemoral joint using magnetic resonance (MR) images from 16 volunteers (8 male and 8 female). Subjects performed an upright weight-bearing squat with the knee at 60 degrees of flexion inside an open-MR scanner and in a gait laboratory. Quadriceps muscle forces were estimated for each subject using an electromyographic-driven model and input to a finite element analysis. Hydrostatic and octahedral shear stresses within the cartilage were modeled with the tibiofemoral joint in a "neutral" position and also with the femur rotated internally or externally by 5 degrees increments to +/-15 degrees . Cartilage stresses were more sensitive to external rotation of the femur, compared with internal rotation, with large variation across subjects. Peak patellar shear stresses increased more than 10% with 15 degrees of external rotation in 75% of the subjects. Shear stresses were higher in the patellar cartilage compared to the femoral cartilage and patellar cartilage stresses were more sensitive to femoral rotation compared with femoral cartilage stress. Large variation in the cartilage stress response between individuals reflects the complex nature of the extensor mechanism and has clinical relevance when considering treatment strategies designed to reduce cartilage stresses by altering femoral internal and external rotation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A modeling framework to estimate patellofemoral joint cartilage stress in vivo.

PURPOSE Patellofemoral (PF) pain is common among athletes and may be caused by increased subchondral bone stress as a result of increased stress in the cartilage of the femur or patella. This article presents a modeling pipeline to estimate in vivo cartilage stress in the PF joint. METHODS The modeling pipeline uses the finite element method to calculate stresses and strains in the PF joint c...

متن کامل

Femoral component rotation and Laurin angle after total knee arthroplasty.

One of the main problems after total knee arthroplasty is pain in the patellofemoral joint, which in some cases leads to revision surgery. Rotation of the femoral component has a significant influence on the path followed by the patella within the patellofemoral joint. We examined the influence of rotation of the femoral component after total knee arthroplasty on patellar tilt. We retrospective...

متن کامل

Femoral Component Rotation in Patellofemoral Joint Replacement: A Study Protocol for a Prospective Observational Study

Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. The short and mid-term outcomes are related to malposition and unexplained pain. Whether external rotation of the femoral component in isolated patellofemoral joint replacement is required is unclear. The primary aim of this study is to determine the CT-measured femoral component rotati...

متن کامل

Malrotation causing patellofemoral complications after total knee arthroplasty.

Thirty patients with isolated patellofemoral complications after total knee arthroplasty were compared with 20 patients with well functioning total knee replacements without patellofemoral complications. The epicondylar axis and tibial tubercle were used as references on computed tomography scans to measure quantitatively rotational alignment of the femoral and tibial components. The group with...

متن کامل

An articular cartilage contact model based on real surface geometry.

Abnormal, excessive stresses acting on articular joint surfaces are speculated to be one of the causes for joint degeneration. However, articular surface stresses have not been studied systematically, since it is technically difficult to measure in vivo contact areas and pressures in dynamic situations. Therefore, we implemented a numerical model of articular surface contact using accurate surf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 26 12  شماره 

صفحات  -

تاریخ انتشار 2008