Evaluation of Intraneural Ganglion Cysts Using 3D FSE-Cube
نویسندگان
چکیده
Purpose: It is often difficult to definitively diagnose intraneural ganglion cysts with conventional MR imaging and to identify the origin of the cyst in a joint via what may often be a subtle connection [1]. Identification of the joint connection has important clinical implications if it is not addressed surgically, such as: cyst recurrence, incomplete patient recovery, and suboptimal operative outcomes [2-4]. The ideal acquisition for imaging these cysts would be a 3D acquisition with isotropic spatial resolution that would achieve optimum reformatting in all areas within a reasonable scan time. A recently developed technique of a fast-recovery 3D FSE with an extended echo-train acquisition (Cube) overcomes many of the previous imaging shortcomings and meets the above criteria [5]. It is the purpose of this study to demonstrate the clinical utility of 3D FSE-Cube in the evaluation of intraneural ganglion cysts and the important joint connection.
منابع مشابه
Isotropic MRI of the Upper Extremity with 3D-FSE-Cube
Introduction Musculoskeletal MRI is commonly done with two-dimensional fast-spin-echo (2D-FSE) and multiple acquisition planes. This results in anisotropic voxels, partial volume artifact and slice gaps. Three-dimensional fast-spin-echo (3D-FSE-Cube), allows for isotropic voxel acquisition with FSE contrast, diminishing the drawbacks of 2D-FSE while reducing exam time and allowing for image ref...
متن کاملProximal Sciatic Nerve Intraneural Ganglion Cyst
Intraneural ganglion cysts are nonneoplastic, mucinous cysts within the epineurium of peripheral nerves which usually involve the peroneal nerve at the knee. A 37-year-old female presented with progressive left buttock and posterior thigh pain. Magnetic resonance imaging revealed a sciatic nerve mass at the sacral notch which was subsequently revealed to be an intraneural ganglion cyst. An intr...
متن کاملIsotropic Imaging of the Wrist at 1.5T using 3D-FSE-Cube
INTRODUCTION: MRI with two-dimensional fast spin-echo (2D-FSE) requires multiple acquisition planes because of slice gaps and partial-volume artifacts. Volumetric acquisitions with isotropic resolution overcome these limitations, allowing reformations in arbitrary imaging planes from a single acquisition [1-3]. A 3D isotropic fast spin-echo sequence (3D-FSE-Cube) was compared with conventional ...
متن کاملA rare case of intraneural ganglion cyst involving the tibial nerve.
Cystic lesions around the knee are a relatively common occurrence. Several types of cysts have been reported, including synovial, bursal, and ganglion. Ganglion cysts are not lined by synovial cells. Their location is highly variable, with occurrences described in the fat pads near the tibia or femur, muscles, nerves, and arteries. Intraneural ganglia are rare nonneoplastic cysts caused by the ...
متن کاملThree-Dimensional Fast Spin-Echo Imaging without Fat Suppression of the Knee: Diagnostic Accuracy Comparison to Fat-Suppressed Imaging on 1.5T MRI
PURPOSE To evaluate the diagnostic performance of three-dimensional fast spin-echo (3D FSE-Cube) without fat suppression (NFS) for detecting knee lesions, using comparison to 3D FSE-Cube with fat suppression (FS). MATERIALS AND METHODS One hundred twenty-four patients who underwent 1.5T knee magnetic resonance imaging (MRI) scans and 25 subsequent arthroscopic surgeries were retrospectively r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009