T2 accuracy on a whole-body imager.
نویسندگان
چکیده
MR oximetry requires a T2 measurement that is accurate within 5% in vivo. Simple methods are susceptible to signal loss and tend to underestimate T2. Current methods utilize RF pulses or RF cycling patterns that prevent signal loss at each data acquisition. However, using these methods with imperfect pulses, T2 tends to be overestimated due to temporary storage of the magnetization along the longitudinal axis where it decays more slowly with a time constant T1 > T2. To reduce the T1 dependence while preventing signal loss, we utilize simple 90x180y90x composite pulses and good RF cycling patterns. These trains are critical for T2 accuracy over typical ranges of RF and static field inhomogeneities and refocusing intervals. T1 signal decay during each 90x180y90x pulse must be accounted for to yield accuracy within 5% when the pulse-width is 10% or more of the refocusing interval. A simple correction scheme compensates for this T1-related error effectively.
منابع مشابه
I-45: Advance MRI Sequences in Pelvic Endometriosis
Background: To assess MRI in diagnosing endometriotic lesions, emphasizing T2*weighted imaging efficacy. Materials and Methods: This prospective study of 48 females (22-38 years, average 29.6) clinically suspected of endometriosis from September 2009 to April 2012. MRI was performed with a 1.5 T imager (Siemens) with a body array coil. T1, T2 and T2* weighted (2D-FLASH) sequences were obtained ...
متن کاملHigh Resolution in Vivo Magnetic Resonance Imaging of the Skin and comparison to High Frequency Ultrasound
For noninvasive imaging and characterization of the skin, high resolution imaging techniques have to be applied. While high frequency ultrasound (HFUS) achieves a resolution in the range of 10 μm, magnetic resonance imaging (MRI) on a 1.5 Tesla, special equipped clinical whole body imager obtains a resolution of several 10x10 μm in plane and several 100 μm slice thickness [1]. Additionally, MRI...
متن کاملIn-Vitro Evaluation of Pre- and Post-Compression States of Human Articular Cartilage Using MRI at 3 Tesla
The purpose of this study was to evaluate changes of several MR parameters (T1, T2 and ADC) before and after compression in human cartilage samples using unique microimaging compression system. Cartilage samples were prepared from joints of 10 patients, who underwent a total knee joint replacement. Study was performed on a Bruker 3T Medspec whole-body scanner (Bruker, Ettlingen, Germany) using ...
متن کاملInvestigating the Effect of Exposure to Whole Body Vibration on Mental Performances of 20-29 Years Old Male
Background and Aim: Vibration, especially whole body vibration, is one of the most important physical harmful factors in industrial environments as well as vehicles. Exposure to whole-body vibration can cause different mental and physiological reactions in humans. This study aimed to investigate the effect of exposure to whole body vibration on the mental performances of 20-29 years old males i...
متن کاملDiffusion imaging of the human brain: a new pulse sequence application for a 1.5-T standard MR system.
We developed a new pulse sequence and investigated whether the anisotropic diffusion in the human brain can be detailed with a standard whole-body MR imager. Apparent diffusion coefficient maps were produced by the proposed sequence using a 1.5-T MR unit. The sequence employed simultaneous application of three orthogonal gradients to achieve an optimal signal attenuation for imaging the brain w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 38 5 شماره
صفحات -
تاریخ انتشار 1997